A proper draft setting is crucial to the successful burning of solid fuels.  Draft refers to the amount of air 
flowing through the burn chamber/firebox of your unit.  Too much or too little draft will cause your unit 
to burn improperly and may result in the fire burning out.  Please follow these guidelines carefully as you 
operate your unit to achieve maximum efficiency and enjoyment. 
 

9

 

The amount of draft required for your unit to burn properly will depend upon your installation and the 
fuel you use. You can set your draft by looking at the flame and following these guidelines.  The 
manual draft knob is the rod and knob on the left side of the unit or the handle on the back of the unit.  
Pulling the knob out increases the draft and pushing the knob in decreases the draft if the damper is on 
the back of the unit you trying it up will increase draft and turning to a 90 deg position will decrease.  
A little movement of the knob goes a long way to changing the flame.  It may take several trial and 
error adjustments on the draft to achieve the correct setting. 

 

9

 

The flame should be an “active” flame.  A flame that moves around lazily and emits visible smoke 
needs more draft.  To give the fire more draft, pull the damper out 1/8” and check the flame again.  If 
the status of the flame has not changed, move the damper another 1/8” until you get a clean “dancing” 
flame. 

If moving the damper does not change the fire, you might have negative pressure in the 

home.

 

 

9

 

The base of the flame should be blue in color and the top of the flame should be white will some 
yellow.  

 

9

 

If the flame does not have enough draft, fuel will build up in the firepot and eventually smother the 
flame.  If this happens, or if you notice the firepot is filling up with partially burned fuel, open the 
damper 1/8” at a time until the fire is clean and dancing. If this continues and moving the draft knob 
does not change anything, you probably have a negative air problem and should have a service tech 
inspect your installation.  

Do not operate the unit if smoke is being pulled into the home. 

 

9

 

If the flame has too much draft, the flame will look like a torch in that it will be moving rapidly and 
blowing fuel out of the firepot.  If you find that you have this condition, move the damper inward 1/8” 
at a time until the condition of the flame changes. 

 

9

 

If the fuel crusts over, you will need to check into the fuel quality.  This will also be a problem if you 
do not have outside air hooked up or if your home is starving for fresh air. 

 
 
 
 
 
 
 
 
 

SETTING THE DRAFT 

Содержание WINACI

Страница 1: ...e pressure All chimney connections elbows and fittings must be airtight Proper venting practices must be followed Consult with a venting professional 9 Ashes must be disposed of in a metal container w...

Страница 2: ...tures 36 Glass Maintenance Adjustment Removal and Replacement 37 Circuit Board Functions 38 39 Setting the Draft 40 Wiring Diagram AC DC 41 42 Draft Slide Gate Adjustment 43 Solar Panel Connections 43...

Страница 3: ...American Energy Systems Inc manufacturer of the MagnuM Winchester Appliances reserves the right to alter its products their specifications and or price without notice Safety tested and EPA exemption t...

Страница 4: ...tove or it could be that there is a serious lacking of good quality air in the home caused by negative pressure If you have done any remodeling or if this is a newer home it is a very real possibility...

Страница 5: ...burning fuels not approved for this appliance it will void the warranty and no service warranty will be allowed 9 The MagnuM models will burn high ash content fuels but will require additional mainten...

Страница 6: ...9 Check your corn for foreign objects Your stove warranty will not cover damage done to your stove due to foreign objects in the fuel supply 9 Do not carry your corn supply over into the next heating...

Страница 7: ...n cleanings Only wood pellets manufactured to the Association of Pellet Fuel Industries A P F I standard for residential pellet fuels are recommended Look for A P F I registration number on the back o...

Страница 8: ...le you are attaching the leg The casting could break if bound or dropped NOTE It is best to attach the legs on one side first and then lift the unit up level to attach the other side You can also atta...

Страница 9: ...ection must be 3 8 inch minimum thickness non combustible material or equivalent extending beneath heater and to the front side rear as indicated CHIMNEY AND CONNECTOR 3 LISTED PELLET VENT ONLY NOTE R...

Страница 10: ...ignite grass plants or shrubs located in the vicinity of the termination The grade surface must not be a lawn Distance from bottom of termination and public walkway is 7ft 2 1m minimum 9 Distance to...

Страница 11: ...h should not exceed 30 feet Diagram 11 1 Component Equivalent Length Equivalent Pipe Length Horizontal Straight Pipe Actual Length in ft x 1 0 Horizontal Pipe 1 x 2 1 3 ft Vertical Straight Pipe Actua...

Страница 12: ...fresh air to the home so that the MagnuM appliance does not become the fresh air source 4 Only non combustible piping 3 inches in diameter is approved to use for outside air connections straight or f...

Страница 13: ...local building codes fire codes and the safety listing tag on the inside hopper lid An outside air source must be connected to the stove and can be brought in through the sidewall or vented crawl spac...

Страница 14: ...RE MANDATORY FOR INSTALLATION IN A MOBILE HOME 1 Stove must be permanently bolted to the floor 2 Stove must have permanent outside air source 3 Stove must be permanently electrically ground to the ste...

Страница 15: ...the pellet vent manufacturer s instructions Connect the pipe and lock the joints as directed by the pellet vent manufacturer and secure the vent pipe to the flue collar on the back of the stove Add a...

Страница 16: ...te The pipe lengths shown are for reference only Your actual pipe length requirements may differ SINGLE WALL PIPE SHALL NOT BE USED FOR ANY INSTALLATION HORIZONTAL INSTALLATION SHALL BE A MAXIMUM OF 5...

Страница 17: ...and presence of all necessary parts including a chimney cap prior to making the connection 3 This stove may be connected to an existing ceiling mounted factory built chimney with a diameter of 4 6 or...

Страница 18: ...s ash buildup premature failure of exhaust system staining of the house siding and serious creosote buildup This installation should not be used in a cold climate area Storm Collar Note This type of i...

Страница 19: ...wo terminals on the back of the control panel When the room temperature drops below the thermostat setting the thermostat switch will close allowing the stove to operate at the medium or higher settin...

Страница 20: ...to the two terminals on the back of the control panel When the room temperature drops below the thermostat setting the thermostat switch will close allowing the stove to operate at the medium or high...

Страница 21: ...21 MAGNUM WIN INSERT INSTALLATION...

Страница 22: ...22 WIN INSERT INSTALLATION cont Siding Use only rigid Pellet Vent pipe Framing Chimney cap Storm Collar Seal Plate 3 75mm Minimum Clearance Around vent 6 150mm min 16 375mm minimum 6 150mm minimum...

Страница 23: ...st use some type of support bolt to hold and level the unit not provided For a raised Hearth you can have a decorative skirting made by your installer to finish off the front of the unit The skirting...

Страница 24: ...resh air intake either out the back of the fireplace cavity or down and out to an outside air source Running the fresh air up and out the top of the chimney can cause excessive draft issues Your insta...

Страница 25: ...25...

Страница 26: ...26 Fireplace Insert Shroud Installation Diagram...

Страница 27: ...27 Thermostat wire connection Low voltage thermostat Molex Plug 24 volt thermostat hookup...

Страница 28: ...p to prevent moisture from reaching terminals see diagram 8 Connect the red positive lead to the positive battery terminal 9 Connect the black negative lead to the negative battery terminal 10 Reconne...

Страница 29: ...is not started within the minimum cycle time the auger will stop feeding and you will need to start the cycle over again Pushing and holding the auger switch allows you to prime the auger and add fue...

Страница 30: ...n allows you to prime the auger and add fuel to the firepot automatically Press and hold the button until you have the right fuel load Do not continue to hold the auger button under normal operation a...

Страница 31: ...moving the control switch to the desired operating position B Select the most efficient burn by adjusting the air damper control rod in or out An air damper closed too much will produce a lazy and sl...

Страница 32: ...LEANERS ALLOW ASH TO ESCAPE INTO THE ROOM AIR HOWEVER VACUUMING Use an approved Ash vacuum system IS RECOMMENDED OCCASIONALLY TO AID IN SEASONAL CLEANING AND KEEP THE UNIT FREE OF EXCESS ASH DISCARD T...

Страница 33: ...ldup of ash After cleaning push the rake handle in until it stops COMBUSTION BLOWER Over the course of the heating season dust and ash may collect on the blades of the combustion blower Periodically t...

Страница 34: ...s needed If you have pets the convection blower will need to be cleaned regularly as the pet hair will clog up the blades and motor windings and cause premature wear overheating and failure of the blo...

Страница 35: ...that they will be ignited in the chimney and produce damage to the chimney or even possibly destroy the home Clean the chimney as often as needed and never go more than one 1 year without a flue clea...

Страница 36: ...unit overheats it will shut itself down safely The unit may not be restarted until it has cooled and the reset button is depressed See Thermodisk location section If the auger does not turn after cle...

Страница 37: ...is not sitting on top of any obstructions The glass will break when tightening the screws if the glass is on the gasket Hold the glass toward the top of the door glass channel when tightening CLEANIN...

Страница 38: ...ong periods of time on the highest heat level setting Optimum efficiency is achieved by using lower settings 2 or 3 It is also recommended that the unit not be run for extended periods of time on the...

Страница 39: ...ee 3 separate modes of operation switch located on top of board The manual setting allows the operator to choose heat level setting changes The T STAT setting allows the operator to set the high heat...

Страница 40: ...oke needs more draft To give the fire more draft pull the damper out 1 8 and check the flame again If the status of the flame has not changed move the damper another 1 8 until you get a clean dancing...

Страница 41: ...41 AC MODEL WIRING DIAGRAM WARNING DISCONNECT POWER BEFORE SERVICING THIS UNIT DHC 3000 AC board...

Страница 42: ...42 DC MODEL DDC 3000 WIRING DIAGRAM WARNING DISCONNECT POWER BEFORE SERVICING THIS UNIT...

Страница 43: ...43 OPTIONAL SOLAR PANEL CONNECTIONS WARNING Use a 3 AMP 50 volt diode on the positive lead between the solar panel and battery as shown in the diagram below...

Страница 44: ...g plate as shown If the unit needs a draft correction adjustment loosen the bolts see above and then rotate the slide gate a few degrees at a time until the proper operation of the unit is achieved NO...

Страница 45: ...r and then apply slight pressure to secure the threads Do not over tighten the igniter assembly If you over tighten the igniter assembly it may ruin the igniter Crimp and attach the terminal ends to t...

Страница 46: ...rly Pull out to increase fire burn 9 Push ash cleanout slides in 9 Check gasket seal around the door If the door is loose adjust the handle latch A small adjustment can be made to the door seal by adj...

Страница 47: ...disk 9 Clean out auger system 9 Have your MagnuM reseller diagnose the problem and replace parts if needed Stove runs for 10 minutes and then shuts down Exhaust gas is not up to temperature Started on...

Страница 48: ...xhaust system with RTV high temperature silicone sealer 9 Use approved ash vacuum 9 Correct negative pressure situation 9 Pull the insert away from the fireplace opening Thoroughly clean the opening a...

Страница 49: ...clean combustion air Dirty or plugged stove or venting Poor exhaust vent configuration Negative pressure present in the home Exhaust fan motor going out Use combustion enhancement system 9 Dirty wet...

Страница 50: ...Fan MF3541 MagnuM Baby Countryside WIN AC Convection blower RP2045 F 110 N O POF Switch interchangeable with F 140 F 150 RP2050 L 225 N C Switch manual reset MagnuM Baby C S WIN Essex RT080 MagnuM Ba...

Страница 51: ...ion air hooked directly to the unit 3 was not operated and maintained in strict accordance with the manufacturer s instructions local or national codes or 4 was subject to abuse misuse negligence or a...

Страница 52: ...52 SERVICE RECORD DATE SERVICE OR CLEANING PERFORMED This record must be sent in when any warranty claims are made...

Отзывы: