Magnum Dimensions 24/3000H-3PH Скачать руководство пользователя страница 1

ISO 9001:2000 Certified Company

Models

24/3000H-3PH

24/4500H-3PH

24/6000H-3PH

Including Options:

R6:

 Remote switch 24Vdc

 OWNERS MANUAL

    

January 2016

DC to AC Power Inverters

120015

E

Manufacturer of Dimensions

TM

 Inverters

4467 White Bear Parkway

St. Paul, MN 55110

Phone:  651-653-7000      Fax:  651-653-7600

E-mail:    [email protected]

Web:    www.dimensions.sensata.com

Form 120015

Содержание 24/3000H-3PH

Страница 1: ...ing Options R6 Remote switch 24Vdc OWNERS MANUAL January 2016 DC to AC Power Inverters 120015E Manufacturer of DimensionsTM Inverters 4467 White Bear Parkway St Paul MN 55110 Phone 651 653 7000 Fax 651 653 7600 E mail inverterinfo sensata com Web www dimensions sensata com Form 120015 ...

Страница 2: ...and capacitor that may produce a spark Do not mount in a confined battery or gas compartment CAUTION Working in the vicinity of lead acid battries is dangerous Batteries gener ate explosive gases during operation There is a risk of acid exposure There is also a risk of high current discharge from shorting the battery that can cause fire and explo sion CAUTION Be sure the inverter is turned OFF dur...

Страница 3: ...ithin 18 inches of the battery Cable gauge Line fuse 24 3000H 3PH 2 0 400 amp 24 4500H 3PH 3 0 500 amp 24 6000H 3PH 4 0 600 amp 3 05 3 Use only an approved fuse holder with a U L listed fuse as indicated above 3 05 4 Using smaller input cable or longer length will greatly degrade the inverter peak performance IMPORTANT NOTE FOR VEHICLE INSTALLATION Do not use the vehicle chassis as the negative re...

Страница 4: ...ocked 5 03 4 If the above steps are completed and the inverter still will not operate satisfac torily call Sensata for a return authorization number 3 06 3 The switch should be mounted at a convenient location in a listed outlet box with approved strain relief 3 06 4 The remote switch should be connected to the violet wire marked Re mote Switch Hookup in the wiring compart ment Positive 12 battery...

Страница 5: ...or units with a model designation ending in R24 Customer supplied On Off Switch Fuse 24 Volt Auxiliary Battery Pack 12 VDC Ground L1 L3 Neutral L2 Violet wire Output Circuit Breaker Running Time Meter BatteryVoltage Indicators On Off Switch ...

Страница 6: ...rranty to the original purchaser of those goods subject to the qualifications indicated Sensata warrants to the original purchaser for use that the goods or any component thereof manufactured by Sensata will be free from defects in workmanship from the date of purchase for the period listed on the product label provided such goods are installed maintained and used in accordance with Sensata and th...

Отзывы: