41
Connection type
On the left of the rear panel of LED-540, there are two 3.5 mm headset jacks,
one marked as“TX”for the communications signals sent port; another is“RX”
as a communication signal receiver port. In order to achieve multi machine
connection, we need to connect all the machines according to the following
picture.
TX
RX
TX
RX
TX
RX
TX
RX
In the above diagram, the arrows represent 3.5 mm headset plug, and
communication signals are always from“TX”port sent to“RX”port. This is a
cyclic annular, its advantage is
:
A.
any of LED-540 can be a starting point of the communication signal,
namely operating terminal can be arbitrary machine of the ring.
B.
can easily add or remove one unit machine from the circular link
structure.
Multi machine load template
When many machine state is established (i.e. connected the machines well
according to the above mentioned“Multi machine connection mode”will
machine connect), to press “MODE” function shortcuts in any one LED-540
front panel, all the machines will enter the template loading shortcut menu.
Please return“
”[
33] to check details instruction.