55
Control unit MGC mTripod
Description of menus and parameters
11. Select input "Input 7 [ ]".
12. Invert the function of the input with the right button « ».
√
Your selection is marked with the symbol [ X ].
13. Use the left button « » to leave the "Settings" menu.
√
The menu "Invert In-/Outputs" is displayed.
14. Press the left button « » repeatedly until the operational view is
displayed again.
Input IN7 and therefore the assigned function "Illumination off" is inverted. In
the menu "Information ()", the input IN7 with inverted function is marked with
a "|"; in this example, it is "IN7: | Illumination off".
6.4
"Service" menu
This menu is only intended for Magnetic's service and only accessible with a
password.
6.4.1
Gate HW
Operational view > Main menu > Service > Gate HW
Parameter
Description
Homing offset
Mechanical tolerances can result in the blocking arm not being exactly in the
middle position after homing. You can use this parameter to compensate for
the deviation. Negative values correct the deviation to the left. Positive
values correct the deviation to the right.
The setting is only accepted after homing.
To determine the suitable setting value, display the angle of rotation on the
operating display
. Manually press the blocking arm to
the desired zero position. Enter the displayed rotation angle for the "Homing
offset" parameter.
Setting range
›
–7° to +7°
Factory setting
›
0°