Electrical connection
8.3
Connecting the mains cable
IMPORTANT!
The wire cross-section of the mains cable must be between 1.5
and 4 mm². Observe national provisions on line length and
associated line cross-section.
Prerequisites
›
The housing is open.
ä
1. Disconnect the system from the power supply. Ensure that the system is
powered down. Secure against reactivation.
DANGER
Mortal danger by electric voltage!
2. Strip mains cable and strands according to the following figure.
20
8
30
8
2
3
1
Mag0081
0
Fig. 32: Stripping (dimensions in mm)
1 Phase
2 Zero conductor
3 Protective earth conductor
3. Carefully lead the mains cable through the housing to the connection
compartment and fasten it with the brackets.
4. Connect the mains cable to the terminals X1: Connect L / N / PE.
ä
Wiring
diagram, separate document.
5. Attach mains cable to the tabs with 2 cable ties.