Magnetic MGCplus Скачать руководство пользователя страница 1

Description

Pedestrian gate mWing
MHTM™ FlowMotion®

Control unit MGCplus

Doc.ID: 5817,0033EN

Version 00

Содержание MGCplus

Страница 1: ...Description Pedestrian gate mWing MHTM FlowMotion Control unit MGCplus Doc ID 5817 0033EN Version 00...

Страница 2: ...2 Control unit MGCplus MAGNETIC AUTOCONTROL GMBH Grienmatt 20 D 79650 Schopfheim Germany Phone 49 7622 695 5 Fax 49 7622 695 802 info magnetic germany com www magnetic access com...

Страница 3: ...control unit 15 3 3 Special operating modes 16 3 4 Control of the passages with Control direction 1 and or Control direction 2 17 3 4 1 Explanations 17 3 4 2 Parameter Control variant Option Variant...

Страница 4: ...direction 49 6 2 4 5 Tailgating 50 6 2 5 Safety 51 6 2 5 1 Forced opening 51 6 2 5 2 Lock wings autom 51 6 2 5 3 Warning light barriers PE beams 52 6 2 6 Signalling 52 6 2 6 1 Buzzer 52 6 2 6 2 GED no...

Страница 5: ...tion 64 7 1 Safety in troubleshooting 64 7 2 Malfunctions pedestrian gate 65 7 3 Event warning and error messages in the display 66 7 3 1 Event warning and error messages Logic control Control unit 67...

Страница 6: ...6 Control unit MGCplus...

Страница 7: ...name and the firmware ver sion FW Version are displayed in the Firmware menu System Control unit Firmware Firmware ID Version 49160013 mWing 1 0 0 Table 1 MGCplus control unit firmware version IMPORTA...

Страница 8: ...nts as well as bodily injuries and property dam age Warning Notes DANGER The signal word DANGER points to an immediately dangerous sit uation which leads to death or severe injuries if it is not avoid...

Страница 9: ...well as information for an efficient and trou ble free operation 1 2 2 Abbreviations used Abbreviation Description Contr Controlled OM Open mode D1 Direction 1 passage direction 1 D2 Direction 2 passa...

Страница 10: ...ant mechanic plant fitter assembly mechanic assembly fitter or has a comparable technical education Has completed training as an electrical safety expert Has additional knowledge and experience Knows...

Страница 11: ...1 Paid MGCplus Master PE receiver Slave PE transmitter 1 2 3 4 4 5 5 1 6 3 Fig 1 Position of the light barriers PE beams and definitions shown here is C module see following page for descriptions 1 S...

Страница 12: ...to the passage direction from the Unpaid zone to the Paid zone Table 4 Definitions 2 2 Unauthorised access attempts The control unit differentiates between different kinds of unauthorised access attem...

Страница 13: ...is closed No validations are accepted in any di rection No passage is possible If a person enters the pedestrian gate the control unit interprets this as an unauthorised access at tempt Contr D1 Close...

Страница 14: ...time Only then can a person pass the pedestrian gate in direction 2 Free D1 Contr D2 Free direction 1 Controlled direction 2 See description Contr D1 Free D2 but in reverse Free D1 D2 Free direction 1...

Страница 15: ...unctions are only effective in the following cases The function Control di rection 1 is assigned to an input or the function Control direction 2 is as signed to an input or the functions Control direc...

Страница 16: ...control unit of the pedestrian gate must be reset If the critical error continues to appear a service technician is required Emergency mode If an input is set with the Emergency open function or if a...

Страница 17: ...n the corresponding direction is possible Parameter Control variant Use this parameter to select the mode for the Control direction 1 Control direction 2 and Control open mode inputs Variant 1 This va...

Страница 18: ...ase also note the parameter descriptions Control variant and Delay permanent open The following symbols and abbreviations are used in the tables Symbol Description Set Not set Not relevant OM Open mod...

Страница 19: ...not set to set at in put Control direction Permanent signal at in put Control direction Resulting operating mode Resulting control unit behaviour 1 2 1 2 1 2 Invalid This variant is available in the f...

Страница 20: ...direction 2 can be performed the passage in direction 1 must be com pleted Contr D1 Free D2 Process passage in direction 1 Before the validated passage in direction 1 can be performed the passage in...

Страница 21: ...Control variant Input Con trol direction Validation by changing from not set to set at in put Control direction Permanent signal at in put Control direction Resulting operating mode Resulting control...

Страница 22: ...irection 2 can be performed the passage in direction 1 must be com pleted Contr D1 Free D2 OM Process passage in direction 1 Before the validated passage in direction 1 can be performed the passage in...

Страница 23: ...inputs you assign certain functions to the inputs Exam ple If you parameterise the Emergency open function for input IN1 you must connect a fire alarm signal to this input If the signal is interrupted...

Страница 24: ...every state change not set to set you add a validation in direction 1 If the signal is longer than the time set for the Delay permanent open pa rameter the free passage in direction 1 is possible Pag...

Страница 25: ...d on When this input is set the illumination assigned to the RGB1 red RGB2 blue etc functions is turned off No access Page 13 chapter 3 1 Free D1 D2 Page 13 chapter 3 1 Free D1 D2 OM Page 13 chapter 3...

Страница 26: ...lay output 6 Wings closed Table 13 Factory settings Digital outputs and Relay outputs Function Description Outputs that you assign this function to are deactivated Error When the control unit detects...

Страница 27: ...resent This output is activated when a validated person is still in the passage Val pers present D1 This output is activated when a validated person who entered on side 1 is still in the passage Val p...

Страница 28: ...has hit an obstacle when opening or closing This output is activated for 10 s Warning light barri ers PE beams This output is activated if one of the light barriers PE beams is occupied for longer tha...

Страница 29: ...language English Change the menu language as follows The operational view is displayed Mag01021 10 FlowMotion mWing 1 192 168 115 242 Fig 2 Example Operational view 1 Press right operating button 2 Ac...

Страница 30: ...n System Main menu Fig 4 View Main menu Settings 4 Select the System menu with the two middle buttons Mag01030 Setings In Outputs Information System Main menu Fig 5 View Main menu System 5 Confirm sel...

Страница 31: ...22 English Language Fig 7 View Language English 8 Select the language German with the two middle buttons The language German has a dark background French Mag00823 German English Language Fig 8 View La...

Страница 32: ...button if you do not want to save the changes The menu language English remains active 11 Confirm safety prompt with the right button The new menu lan guage German is activated The following view is...

Страница 33: ...ollowing view is displayed Mag00818 0 Password Fig 12 View Enter password 1 Use the two middle buttons to enter the first digit of the password 2 Use the right button to select the second digit of the...

Страница 34: ...word Fig 14 View Enter fourth digit of the password 7 Use the two middle buttons to enter the fourth digit of the password 8 Confirm the password with the right control button 5 3 Control unit element...

Страница 35: ...ssage direction 2 here closed no validations 5 Hold open time in passage direction 2 here closed no validations 6 IP address 7 Operating display here passage direction 1 enabled 8 Current function of...

Страница 36: ...u Make all settings in the menu Main menu Leave current menu level The next higher menu level is displayed Call next lower menu level Select desired option or desired value When the desired option was...

Страница 37: ...k function There is information Check the Information menu To do this press the left operating button There is a warning Check the Information menu To do this press the left operating button There is...

Страница 38: ...om access You can apply the access to the main menu with password protection Page 63 Main menu password 5 8 Parameterise value Example Change hold open time The operational view is displayed Page 29 F...

Страница 39: ...hanges are not to be saved press the left button The previ ous hold open time remains active The Settings menu is displayed 12 Press the left button repeatedly until the operational view is dis played...

Страница 40: ...essages Display of the error warning or event messages that occurred since the last voltage reset including date and time Use the and buttons to navigate through the messages If no messages are presen...

Страница 41: ...variant is automatically selected Page 19 chapter 3 4 2 and Page 21 chapter 3 4 3 Factory setting Variant 1 Delay permanent open You use this parameter to specify whether and after what time the perm...

Страница 42: ...y Table 18 Operating mode 6 2 2 Validations Operational view Main menu Settings Validations Parameter Description Hold open Time Change Set the hold open time The hold open time is started by an openi...

Страница 43: ...ng 1 s Close delay set Shows the set close delay Close delay Remaining time Shows the remaining close delay Left direction 1 Shows the remaining validations in direction 1 Left direction 2 Shows the r...

Страница 44: ...g speed Select the speed for opening the wings Options Slower Slow Medium Fast Faster Factory setting Fast Closing speed Select the speed for closing the wings IMPORTANT The closing speed for unauthor...

Страница 45: ...eams is ena bled Activated X The test of the safety light barriers safety PE beams is dis abled Factory setting Inactive Impact response Open Select the response for obstacle detection during the open...

Страница 46: ...sed via the Impact response Close parameters of the Intrusion Wrong direction and Tailgating menus Page 48 chapter 6 2 4 3 up to Page 50 chapter 6 2 4 5 Options None The control unit attempts to conti...

Страница 47: ...to be entered depend on the installed blocking element The values to be entered are on a label that is attached to the blocking ele ment Adjust values for safe operation 1 Select the Low energy menu...

Страница 48: ...ged values in the Low energy menu Options No action Adopt values Status Shows whether the new values are correct or incorrect Readback 1 Shows the current settings for the values S and T for Wing 1 Re...

Страница 49: ...D2 Example Contr D1 Free D2 If a validation is pending in direction 1 and a person enters the pedestrian gate in direction 2 this is an unauthorised access attempt of the type Wrong direction If you s...

Страница 50: ...haviour of the wings in case of an unauthorised access attempt of the Tailgating type If you select the Activated X option the wings will not be closed in the event of an unauthorised access attempt o...

Страница 51: ...t on forced opening After the control unit has detected an attempt on forced opening the con trol unit locks the wings for the selected time When the time expires the control unit unlocks the wings an...

Страница 52: ...s to 60 s 0 s The output Warning light barriers PE beams is not set Factory setting 0 s Table 28 Warning light barriers PE beams 6 2 6 Signalling 6 2 6 1 Buzzer Operational view Main menu Settings Sig...

Страница 53: ...no validations are pending and no free passage in that direction is possible As soon as a validation is pending or the direction is permanently free the GED turns green Standby green The GED is green...

Страница 54: ...ds 5 Hz Factory setting Variant 2 On intrusion Select the display pattern for the On intrusion event Options Page 55 section Display pattern on the GED Factory setting Pulse red 2 5 Hz On wrong direct...

Страница 55: ...z GED flashes in red with a frequency of 5 Hz Pulse green 5 Hz GED flashes in green with a frequency of 5 Hz Double pulse short red GED flashes in red twice every second with a pulse of 100 ms Double...

Страница 56: ...ndom hit validation is confirmed with a 0 V pulse at the Random check function input Operational view Main menu Settings Random check function Parameter Description Mode Set the function of the random...

Страница 57: ...justed Setting range 10 to 10000 Factory setting 1000 Count of hits Set the number of hits to be generated in the set Count of hits IMPORTANT The value for the Count of hits parameter can be a maximum...

Страница 58: ...nction 6 2 8 Home offset This menu is available only for pedestrian gates with swing wings Operational view Main menu Settings Home offset Parameter Description All wings You can correct or teach in t...

Страница 59: ...2 1 In direction 1 Operational view Main menu Information People counter In direction 1 Parameter Description Passages total Shows the number of all validated and non validated passages in direction 1...

Страница 60: ...tion type in direction 1 Tailgating Shows the number of unauthorized access attempts of the Tailgating type in direction 2 Table 36 People counter In direction 2 6 4 3 Light barriers PE beams Operati...

Страница 61: ...nnected via LAN Internet access is available All IP settings are configured correctly Via Magnetic you can purchase additional hardware to connect the control unit to the Internet without connecting i...

Страница 62: ...ngs All settings in the IP Settings menu are restored to de fault settings To factory setting The stored parameters in the memory area Factory settings are adopted as operating settings To FW defaults...

Страница 63: ...her call the operational view or switch the voltage supply on or off Options Inactive You can change the main menu without entering a password Active You can change the main menu only after entering a...

Страница 64: ...bleshooting can cause severe injuries Observe possible movements of the blocking element Defec tive control may lead to inadvertent movement of the blocking element In case of damaged components take...

Страница 65: ...espond ing error message is displayed Depending on error message check components wiring etc MHTM FlowMotion service expert Power supply is present Con trol unit display does not light up Control unit...

Страница 66: ...en for an output this output is deacti vated at pending warnings fail safe Error messages ERROR Faults that cannot be reset by the control unit are displayed as errors The pe destrian gate is put out...

Страница 67: ...otor address setting or defective mo tor electronics Check for correct motor address setting Check the CAN bus wiring Check the settings of the terminating resistance Contact service ERROR 0x3001F003...

Страница 68: ...terminating re sistance Replace the IM16 input ex tension Contact service ERROR 0x50nn3048 0x50nn3049 0x50nn304A 0x50nn304B 0x50nn304C Error during communi cation with an IM16 in put extension install...

Страница 69: ...the two middle operating buttons on the control unit display for 5 s Using the parameter Reboot menu path Operational view Main menu System Reboot Set the input with the Reset function NOTICE Fast re...

Страница 70: ...us Menu setup 8 Menu setup Mag01022 10 FlowMotion mWing 1 192 168 115 242 System Service Main menu Setup Error Warning Event messages Inputs Modul info Outputs In Outputs Information Fig 18 Menu Infor...

Страница 71: ...tion Direction Safety Security Opening speed Closing speed Speed on fraud Signalling Home offset Control variant Delay permanent open Emergency options Hold open time Close delay Left direction 1 Left...

Страница 72: ...Close General Low engery Intrusion Wrong direction Tailgating New value S New value T New value C Adopt new values Status Readback 1 Readback 2 Do not close if free Do not close Disable safety Impact...

Страница 73: ...Warning PE beams Mode Mode wrong direction Validation response On intrusion On wrong direction On tailgating On emergency On error Mode Mode wrong direction Validation response On intrusion On wrong...

Страница 74: ...puts 1 4 Relay outputs 1 6 Operating mode People counter System Reboot Language IP settings Remote support USB drive CAN bus Restore settings Service Cycle counters Operating time Date Time Main menu...

Страница 75: ...Warning People counter Light barriers PE beams In direction 1 In direction 2 Passages total Valid passages Reverted Intrusion Wrong direction Tailgating Passages total Valid passages Reverted Intrusi...

Страница 76: ...76 Control unit MGCplus...

Страница 77: ...Direction 58 Direction 1 See Passage direction 1 Direction 2 See Passage direction 2 Disable safety 45 Intrusion 48 Tailgating 50 Wrong direction 49 Display contrast 38 Display control unit 35 Symbol...

Страница 78: ...nergy 47 M Magnetic MHTM FlowMotion service expert 10 Main menu password 63 Malfunctions Control unit 67 Pedestrian gate 65 Do not close Intrusion 48 Tailgating 50 Wrong direction 49 Do not close if f...

Страница 79: ...2 12 Signalling 52 Speed on fraud 44 Speed Wings 44 Status Low energy 48 Manual validation D1 43 Manual validation D2 44 Max direction 1 43 Max direction 2 43 Menu Information 40 Settings 41 Menu set...

Страница 80: ...sage In direction 1 59 In direction 2 60 Val pers 9 Val pers passed 9 27 Val pers passed D1 27 Val pers passed D2 27 Val pers present 27 Val pers present D1 27 Val pers present D2 27 W Wait for homing...

Страница 81: ...81 Control unit MGCplus...

Страница 82: ...82 Control unit MGCplus...

Страница 83: ...83 Control unit MGCplus...

Страница 84: ...TIC AUTOCONTROL GMBH Grienmatt 20 D 79650 Schopfheim Germany Phone 49 7622 695 5 Fax 49 7622 695 802 info magnetic germany com www magnetic access com Sales partner Doc ID 5817 0033EN Version 00 F1004...