Barrier MHTM
TM
MicroDrive
Parameterising control unit
5815,5001US / Version 02.66
115
10.7.3
Mode 3: Pulse control (bistable)
Typical application
This mode is suitable for barriers on factory premises, etc. that are
little frequented by vehicles. The signal generator may be, e.g. a
wireless button. The barrier must be operated by a person.
Function
The barrier is opened and closed by one command unit (pulse
repetition). Every pulse changes the barrier's movement direction.
The pulse must be present between 100 and 300 ms.
1. Signal: barrier opens
2. Signal: barrier closes
3. Signal: barrier opens
etc.
If another pulse is given during closing, the barrier opens. If
another pulse is given during opening, the barrier opens
completely and closes afterwards for reasons of safety.
Supported input functions
Input function
Signal type
Supported/
Not supported
Open low priority
(opening and closing
alternatingly),
(priority 2)
Permanent signal Supported
Open low priority with
vend count
– Not
supported
Open high priority
(priority 1)
Pulse or
permanent signal
Supported
Opening loop
–
Not supported
Close – Not
supported
Table 37: Supported input functions "Pulse control"
See page 97, chapter 9.4.6 "Digital inputs".
Содержание MHTM MicroDrive
Страница 1: ...Operating Instructions Barrier MHTMTM MicroDrive Doc ID 5815 5001US Version 02 6...
Страница 4: ...Barrier MHTM TM MicroDrive 4 5815 5001US Version 02 66...
Страница 10: ...Barrier MHTM TM MicroDrive 10 5815 5001US Version 02 66...
Страница 178: ...Barrier MHTM TM MicroDrive 178 5815 5001US Version 02 66...
Страница 179: ......
Страница 180: ...Barrier MHTM TM MicroDrive 180 5815 5001US Version 02 66...
Страница 182: ...Barrier MHTM TM MicroDrive Appendix 182 5815 5001US Version 02 66...
Страница 184: ......
Страница 186: ......
Страница 188: ......
Страница 195: ...Barrier MHTM TM MicroDrive 5815 5001US Version 02 6 195...