Installing induction loops under interlocking stone paving
Fig. 20: Installing an induction loop under interlocking stone paving
Dimensions in inch are without parenthesis. Dimensions in mm
are in parenthesis.
1
Barrier housing
2
Paving
3
Loop cable
4
Sand bed
5
Substructure
When installing induction loops under interlocking stone paving,
following points must be observed additionally:
Use only pre-assembled cables.
Install the induction loop in sand only. The induction loop must
not be installed in gravel or split.
The induction loop must not slip or shift or be damaged during
later vehicle traffic.
Keep a minimum clearance between paving and loop cable of
approx. 1.18 in (30 mm).
Содержание MHTM MicroDrive Access Series
Страница 1: ...Operating Instructions Barrier MHTMTM MicroDrive Access and Parking Doc ID 5815 5013US Version 05...
Страница 4: ...Barrier MHTM TM MicroDrive Access and Parking 4 5815 5013US Version 05...
Страница 126: ...Barrier MHTM TM MicroDrive Access and Parking 126 5815 5013US Version 05...
Страница 129: ......
Страница 130: ...Barrier MHTM TM MicroDrive Access and Parking 130 5815 5013US Version 05...
Страница 132: ...Barrier MHTM TM MicroDrive Access and Parking Appendix 132 5815 5013US Version 05...
Страница 134: ......
Страница 136: ......
Страница 138: ......
Страница 140: ......