10
OTHER MENU
Press Enter in standby mode.
Enter the number □
Other menu ■
Press Up or Down button to select Other menu field. Confirm with Enter.
Filling in the internal cylinder. ■
Service □
Printing □
Diagnostics □
Diagnostics and Printing fields are available only if there is a memory card and/or printer
present in the system.
Press Up or Down button to select the desired option. Confirm with Enter.
10.1
Filling in the internal cylinder
Read paragraph Błąd! Nie można odnaleźć źródła odwołania.
Filling in the internal
cylinder.
10.2
Diagnostics
If the device is equipped with a memory card, there is an option of running diagnostics of
the A/C system and obtaining indications concerning possible failures.
The diagnostics option is available after completing the filling phase or by selecting the
appropriate menu option.
Close LP and HP valves
Follow the instructions. Press Enter to confirm. The messages below will be displayed only if
Diagnostics option is available in the Other menu.
Connect HP/LP tubes to the A/C system
Follow the instructions. Press Enter to confirm.
Start the A/C system for checking
To verify correct operation of the A/C system start the engine and keep rotation speed at
1500/2000 r.p.m. Set the lowest cooling temperature in the system and the highest fan
speed. Let the system operate for 10 min. Follow the instructions; confirm with Enter.
Check the values below:
T.E
External temperature, ( C°)
T.I
Internal temperature in the main A/C system, (C°)
P.HP
Pressure shown on HP pressure gauge, (bar)
P.LP
Pressure shown on LP pressure gauge, (bar)
P.HP: bar __._
P.LP: bar __._