IMPULSE
®
•G+ Mini Technical Manual
November 2020
Page 76
5.2.10 Serial Communication Digital Inputs
Provides additional programmable multi-function digital inputs via serial communication.
5.2.11 Brake Delay Timers
This function is used in trolley or bridge applications. It can reduce the mechanical brake wear when the operator
tries to position a load. This function is available only in traverse mode when B03.03 = 04 (Decel With Timer).
Figure 5-20: Brake Delay Timers
Parameter
Name
Function
Range
Default
C09.01
Digital Input Setup
Provides additional programmable digital inputs via
serial communications
0, 5
0
00 Disabled
05 Serial
C09.03
DIO Terminal 1
00-FF
0F
C09.04
DIO Terminal 2
00-FF
0F
C09.05
DIO Terminal 3
00-FF
0F
C09.06
DIO Terminal 4
00-FF
0F
C09.07
DIO Terminal 5
00-FF
0F
C09.08
DIO Terminal 6
00-FF
0F
C09.09
DIO Terminal 7
00-FF
0F
C09.10
DIO Terminal 8
00-FF
0F
C09.11
DIO Terminal 9
00-FF
0F
C09.12
DIO Terminal 10
00-FF
0F
C09.13
DIO Terminal 11
00-FF
0F
C09.14
DIO Terminal 12
00-FF
0F
C09.15
DIO Terminal 13
00-FF
0F
C09.16
DIO Terminal 14
00-FF
0F
C09.17
DIO Terminal 15
00-FF
0F
C09.18
DIO Terminal 16
00-FF
0F
Parameter
Name
Function
Range
Default
C12.01
Brake Jog Delay
Brake set delay time at Jog Control input.
0.0–100.0 sec
0.0 sec
C12.02
Brake Run Delay
Brake set delay time at RUN input.
0.0–100.0 sec
0.0 sec
Frequency
Output
Brake
Command
Jog or Run
Command
Delay
Delay
Содержание IMPULSE G+ Mini
Страница 15: ...IMPULSE G Mini Technical Manual November 2020 Page 15 Figure 2 1 Long Time Storage...
Страница 17: ...IMPULSE G Mini Technical Manual November 2020 Page 17 Figure 2 2 Diagram A Figure 2 3 Diagram B...
Страница 18: ...IMPULSE G Mini Technical Manual November 2020 Page 18 Figure 2 4 Diagram C...
Страница 56: ...IMPULSE G Mini Technical Manual November 2020 Page 56 Figure 5 8 DC Injection Brake Time Calculation...
Страница 181: ......
Страница 182: ...IMPULSE G Mini Adjustable Frequency Crane Controls Technical Manual November 2020...