NOTE:
After changing any H05.XX parameter, power to the VFD must be cycled for the changes to take effect.
NOTE:
After initial communication, if the VFD does not detect communication for H05.09 time, a communication
fault will occur (CE Modbus ERR).
5.6.7 Pulse Inputs
H05.11
Communication Enter Function Select
Select whether or not an Enter Command
is required to save parameter data to VFD
00, 01
00
00 Enter Command must be used
01 Enter Command not required
H05.12
Run Command Method Selection
Select Run Command Method
00, 01
00
00 Bit 0 = Start/Stop Forward Direction
Bit 1 = Start/Stop Reverse Direction
01 Bit 0 = Start/Stop
Bit 1 = Forward/Reverse Direction
Parameter
Name
Function
Range
Default
H06.01
Pulse Input Selection
Sets the function of the Pulse Input Terminal (RP)
00, 03
00
00 Frequency Reference
03 Encoder Feedback
H06.02
Pulse Input Scaling
Sets the number of pulses equal to the maximum
output frequency
1,000 – 32,000 Hz
1440
H06.03
Pulse Input Gain
Sets the gain of the output frequency when the
input frequency is at 100%
0.0 – 1,000.0%
100.0
H06.04
Pulse Input Bias
Sets the output frequency level when the input
frequency is ONE
-100.0 – 100.0%
0.0
H06.05
Pulse Input Filter Time
Sets the input filter time delay constant in seconds
0.00–2.00 sec
0.10
H06.06
Pulse Monitor Selection
Selects which monitor output to use for the Pulse
Train Monitor Output Terminal (MP). Ex: 102
means U01.02 (Output Frequency)
000 – 120
102
000 Not Used
101 Frequency Ref
102 Output Freq
105 Motor Speed
120 SFS Output
H06.07
Pulse Monitor Scaling
Sets the output frequency of the terminal (MP) at
100%. To monitor output frequency simultaneously,
set H06.06 = 102 and H06.07 = 0
0 – 32,000 Hz
1440
Parameter
Name
Function
Range
Default
Содержание IMPULSE G+ Mini
Страница 15: ...IMPULSE G Mini Technical Manual November 2020 Page 15 Figure 2 1 Long Time Storage...
Страница 17: ...IMPULSE G Mini Technical Manual November 2020 Page 17 Figure 2 2 Diagram A Figure 2 3 Diagram B...
Страница 18: ...IMPULSE G Mini Technical Manual November 2020 Page 18 Figure 2 4 Diagram C...
Страница 56: ...IMPULSE G Mini Technical Manual November 2020 Page 56 Figure 5 8 DC Injection Brake Time Calculation...
Страница 181: ......
Страница 182: ...IMPULSE G Mini Adjustable Frequency Crane Controls Technical Manual November 2020...