Parameters
39
A1 8:55
Contract Car Spd
0400.0 ft/min
READY
RUN
USER
FAULT
TORQUE
LIMIT
SUB MENU
DATA ENTRY
8:55 May 20
A0 ADJUST
A1 DRIVE
READY
RUN
USER
FAULT
TORQUE
LIMIT
SUB MENU
DATA ENTRY
A1 8:57
Contract Car Spd
0400.0 ft/min
Min 0.0
Max 1500.0
READY
RUN
USER
FAULT
TORQUE
LIMIT
SUB MENU
DATA ENTRY
Menus
Each menu has a number of sub-menus, see
Figure 32.
Menu Navigation
How these keys in Figure 31 operate is
dependent on the “level” (i.e. menu, sub-menu
or entry level.) In general, the “ENTER” and
“ESCAPE” keys control the level. That is the
ENTER key used to move to a lower level and
the ESCAPE key is used to move to a higher
level. The arrow keys control movement; with
the up and down arrow keys controlling vertical
position. And the left and right arrow keys
controlling horizontal position.
Navigation at the Menu Level
At the menu level, the up and down arrow keys
cause the display to show the sub-menus.
The side arrow keys cause the display to
select which menu is active. When the end is
reached (either up, down, left or right),
pressing the same key will cause a wrap
around.
Each menu will remember the last accessed
sub-menu. The left and right arrow keys will
navigate between these last active sub-menus.
This remembrance of last active sub-menu is
volatile and will be lost at power down.
When any sub-menu is displayed, pressing the
“ENTER” key will place the operator in the sub-
menu level.
Navigation at the Sub-menu Level
When in the sub-menu level, the SUB-MENU
LED on the digital operator is lit. At the sub-
menu level, the positioning keys work slightly
different than they did at the menu level. The
up and down arrow keys now select separate
items in the sub-menu.
Navigation at the Entry Level
When in the entry level, the DATA ENT LED
on the digital operator is lit. At the entry level,
the functions of keys are redefined. The
“ESCAPE” key remains as the key used to
move back to the higher level. The left and
right arrow keys are used as cursor positioning
keys and the up and down arrow keys are
used as increment and decrement keys.
Upon exiting a sub-
menu via the “ESCAPE”
key, the last item number is “remembered”.
The next time this sub-menu is entered, it is
entered at the “remembered” item number.
This feature can be used to obtain quick
access to two monitor values. Two menus one
labeled Display 1 D0 and one labeled Display
2 D0 has the same display items. One item
can be selected under the Display 1 menu and
another under the Display 2 menu. The left
and right arrow keys can then be used to move
back and forth between these two display
items. Remember, that the “remembering” of
sub-menus and sub-menu items is volatile and
is lost at power-down.
Hidden Parameters
There are two types of parameters: standard
and hidden. Standard parameters are
available at all times. Hidden parameters are
for more advanced functions and are available
only if activated. Activation of the hidden
parameters is accomplished by setting of a
utility parameter, HIDDEN ITEMS U2.
See
details in Hidden Items on page 119.
Magnetek Explorer
Magnetek Explorer is a program available at
www.elevatordrives.com. This allows you to
use a computer to download and upload the
parameters in the A and C menus. Version
3.4.5 or later should be used.
Содержание HPV 900 Series 2
Страница 4: ......
Страница 195: ...APPENDIX Dimensions Mounting Holes Weights 173 Figure 46 Frame 2 Dimensions Mounting Holes and Weight...
Страница 196: ...APPENDIX Dimensions Mounting Holes Weights 174 Figure 47 Frame 3 Dimensions Mounting Holes and Weight...
Страница 197: ...APPENDIX Dimensions Mounting Holes Weights 175 Figure 48 Frame 3 5 Dimensions Mounting Holes and Weight...
Страница 198: ...APPENDIX Dimensions Mounting Holes Weights 176 Figure 49 Frame 4 Dimensions Mounting Holes and Weight...
Страница 199: ...APPENDIX Dimensions Mounting Holes Weights 177 Figure 50 Frame 5 Dimensions Mounting Holes and Weight...
Страница 227: ...205 Z Z MARKER LOST 150 Zero Speed Level parameter 47 Zero Speed logic output 105 Zero Speed Time parameter 47...
Страница 228: ......
Страница 229: ......