Fault F0 Menu
125
READY
RUN
USER
FAULT
TORQUE
LIMIT
Fault F0 Menu
F0
Parameter
[Alphanumeric]
Description
Hidden
item
Run
lockout
F1
ACTIVE FAULTS
[F101]
Contains a list of the active faults
N
N
F2
FAULT HISTORY
[F201]
Contains a list of up to the last sixteen faults with time
stamps
N
N
F3
SORTED HISTORY
[F301]
Contains a list of all potential faults and the number of
times they have occurred
N
N
F4
RESET FAULTS
RST ACTIVE FLTS
[F401]
Clears the active faults listed
in F1 submenu
Idle
[S179]
N
N
Enter to rst
[S180]
CLR FLT HIST
[F402]
Clears the Fault History
listed in the F2 submenu
and the Sorted History listed
in the F3 submenu
Idle
[S179]
N
N
Enter to clr
[S182]
Detailed Descriptions
The FAULTS F0 menu does not access
settable parameters; instead, it provides a
means of examining the drive’s active faults
and the fault history.
This menu also allows for clearing of active
faults in order to get the drive ready to return to
operation after a fault shutdown.
ACTIVE FAULTS
(Active Faults)
The active fault list displays and records the
active faults. The faults will remain on the fault
list until a fault reset is initiated.
Press the enter key to enter the active fault list.
Use the up and down arrow keys to scroll
through the active faults.
FAULT HISTORY
(Fault History)
This sub-menu contains a list of up to the last
sixteen faults.
NOTE: The fault history is not affected by the
fault reset or a power loss. The fault history
can only be cleared by a function the F4
RESET FLTS submenu
All faults are on the fault history. The fault
history displays the last 16 faults that have
occurred and a time stamp indicating when
each happened. The time stamp (month-day-
year hour:min:sec) is set in the U11 TIME
submenu.
Press the enter key to enter the fault history.
Use the up and down arrow keys to scroll
through the faults.
SORTED HISTORY
(Sorted History)
This sub-menu contains a list of faults to occur
on the drive with the number of times they
have occurred since the last fault history clear.
F1 8:55
CHARGE FAULT
READY
RUN
USER
FAULT
TORQUE
LIMIT
SUB MENU
DATA ENTRY
F2 8:55
1 CHARGE FAULT
04-22-09 15:53:58
READY
RUN
USER
FAULT
TORQUE
LIMIT
SUB MENU
DATA ENTRY
Содержание HPV 900 Series 2
Страница 4: ......
Страница 195: ...APPENDIX Dimensions Mounting Holes Weights 173 Figure 46 Frame 2 Dimensions Mounting Holes and Weight...
Страница 196: ...APPENDIX Dimensions Mounting Holes Weights 174 Figure 47 Frame 3 Dimensions Mounting Holes and Weight...
Страница 197: ...APPENDIX Dimensions Mounting Holes Weights 175 Figure 48 Frame 3 5 Dimensions Mounting Holes and Weight...
Страница 198: ...APPENDIX Dimensions Mounting Holes Weights 176 Figure 49 Frame 4 Dimensions Mounting Holes and Weight...
Страница 199: ...APPENDIX Dimensions Mounting Holes Weights 177 Figure 50 Frame 5 Dimensions Mounting Holes and Weight...
Страница 227: ...205 Z Z MARKER LOST 150 Zero Speed Level parameter 47 Zero Speed logic output 105 Zero Speed Time parameter 47...
Страница 228: ......
Страница 229: ......