Enrange Flex EM/EX Instruction Manual
April 2019
Page 18 of 19
7. TROUBLESHOOTING
WARNING
THE OPERATOR SHOULD NOT ATTEMPT TO REPAIR ANY RADIO CONTROLLER. IF ANY PRODUCT
PERFORMANCE OR SAFETY CONCERNS ARE OBSERVED, THE EQUIPMENT SHOULD IMMEDIATELY
BE TAKEN OUT OF SERVICE AND BE REPORTED TO THE SUPERVISOR. DAMAGED AND INOPERABLE
RADIO CONTROLLER EQUIPMENT SHOULD BE RETURNED TO MAGNETEK FOR EVALUATION AND
REPAIR. FAILURE TO FOLLOW THIS WARNING COULD RESULT IN SERIOUS INJURY OR DEATH AND
DAMAGE TO EQUIPMENT.
7.1 TROUBLESHOOTING TABLE
Problems
Possible Reasons
Suggestions
No response when
transmitter push
button is pressed
(Improper startup &
settings)
Transmitter low battery
power
Check the transmitter battery level.
Emergency stop button
activated prior to startup
Prior to turning on the transmitter power switch
make sure that the red emergency stop button is
elevated.
Improper startup
procedure
Redo the startup procedure by holding the power
key at “START” position for up to 2.0 seconds and
then release.
Incorrect system RF
channel
Make sure that the transmitter handset and the
receiver unit both have the same channel.
Incorrect Receiver Access
Code
Make sure that the transmitter handset and
receiver unit both have the same Receiver Access
Code.
System out of range
Make sure that the startup procedure is initiated
within 100 meters (300 feet) from the receiver
location.