Enrange Flex EM/EX Instruction Manual
April 2019
Page 13 of 19
5. OPERATING PROCEDURE
5.1 GENERAL OPERATING PROCEDURE
1. Reset the red emergency stop button located on the top left hand side of the transmitter handset
by rotating it either clockwise or counter clockwise. The red button will pop up.
Figure 7
2. Turn on the transmitter power by inserting the black-colored key into the power key slot located
on the top right hand side of the transmitter handset and rotate it clockwise to the “On”
position.
Figure 8
Figure 9
3. After turning on the transmitter power, check the Status LED on the transmitter handset for any
sign of system irregularities (refer to Section 5.3). If the system is normal the Status LED will
light up green for two (2) seconds, then slowly flash green.
4. If there are no signs of any system irregularities, then rotate the power key further clockwise to
the “Start” position for up to two (2) seconds. This will activate the receiver E-Stop.
Thereafter, the same “Start” position will become an auxiliary function with momentary
contact.
Figure 10