Operation
Controls and Indicators
14
MagneMotion
Rockwell Automation Publication MMI-UM002E-EN-P - March 2016
Figure 6-7: E-Stop Wiring Diagram, Single Node Controller
Figure 6-8: E-Stop Wiring Diagram, Multiple Node Controllers
1
1. In this configuration other Digital I/O functions may not be available.
Digital In
Digital In
E-Stop
NC-12 Node Controller
COM
-V
+V
E-Stop
+3 - 24 VDC
Power Supply
Digital In
Digital In
E-Stop
NC-12 Node Controller
COM
E-Stop
Digital In
Digital In
NC-12 Node Controller (8 max)
COM
-V
+V
+3 - 24 VDC
Power Supply