Installation
Option Installation
58
MagneMotion
Rockwell Automation Publication MMI-UM002E-EN-P - March 2016
Install the Pneumatic Controls
The pneumatic fittings on the Precision Locator’s cylinder should be installed before the loca-
tor is mounted on the stand to allow ease of access (refer to
Install the Precision Locators on
).
Figure 5-41: Precision Locator Pneumatic Connections
1.
Install the pneumatic valve that will control the Precision Locator. This procedure
assume the use of a 5/2 valve as described in
Precision Locator Installation
A.
Connect the pneumatic valve control lines to the Host Controller’s Digital I/O.
B.
Connect the valve’s pneumatic input to the facility’s compressed air line.
C.
Connect the pneumatic valve’s #2 output to Open on the Precision Locator’s
pneumatic cylinder.
D.
Connect the pneumatic valve’s #4 output to Closed on the Precision Locator’s
pneumatic cylinder.
E.
Connect the pneumatic valve’s exhaust #3 to a flow control valve. The flow
control valve should be adjusted to limit the pinning time to 100 ms or greater.
Please note that all life estimates are based on a pinning time of at least
100 ms.
F.
Connect the pneumatic valve’s exhaust #5 to a muffler.
2.
If using the optional cylinder position sensors:
•
If installing user-supplied sensors, install them into position and secure as
directed by the manufacturer.