MagneMover LITE User Manual Addendum,
Air-cooled Motors
10003676721
Ver. 01
Copyright © 2019 Rockwell Automation, Inc.
Page 21 of 26
Pneumatic Specifications
The MagneMover LITE air-cooled motors allow a continuous flow of clean, dry air to
provide additional cooling. These motors can be run as normal MM LITE motors by
installing the supplied plugs in the port locations.
Figure 14: Air-cooled Serial Motor Pneumatic Connections
Table 7: Air-cooled Motor Pneumatic Connectors
Label
Description
Connector Type
A1
Air In
12 mm push to connect fitting
A2
Air Out
12 mm push to connect fitting
Air Cooling
A1: Supply air per ANSI 7.0.01-1996,
Quality Standard for Instrument Air
. Do not
exceed 1.0 psig [6.9 kPa] inlet pressure or 4.0 scfm [113 L/min] inlet flow.
A2: Exhaust to atmosphere.
NOTE:
Any hose connected to the A2 port generates a backpressure, which can
limit the cfm capability to satisfy the 1 psi specification.
Pressurizing
A1: Supply air per ANSI 7.0.01-1996,
Quality Standard for Instrument Air
. Do not
exceed 1.0 psig [6.9 kPa] inlet pressure.
A2: Plugged.
In
Out