11
Operation
Other features
FOLLOW ME/TEMP SENSING feature(optional)
NOTE:This feature can be activated from the remote control ONLY. The remote control
overseas a remote thermostat allowing for the precise temperature control at its location.
To activate the Follow Me/Temp Sensing feature, point the remote control towards the
unit and press the Follow Me/Temp Sensing button. The remote display is actual
temperature at its location. The remote control will send this signal to the air conditioner
every 3 minutes interval until press the Follow Me/Temp Sensing button again. If the unit
does not receive the Follow Me/Temp Sensing signal during any 7 minutes interval, the
unit will beep to indicate the Follow Me/Temp Sensing mode has ended.
AUTO-RESTART
If the unit breaks off unexpectedly due to the power cut, it will restart with the previous
function setting automatically when the power resumes.
WAIT 3 MINUTES BEFORE RESUMING OPERATION
After the unit has stopped, it cannot be restarted operation in the first 3 minutes. This is
to protect the unit. Operation will automatically start after 3 minutes.
AIR FLOW DIRECTION ADJUSTMENT
The louver can be adjusted automatically. Adjust the air flow direction automatically (NOTE:
On some models the louver can be adjusted manually only) :
-When the Power is ON, the louver opens fully.
-Press the SWING button on the panel or remote control to initiate the Auto swing
feature. The louver will swing up and down automatically.
-Please do not adjust the louver manually.
Water drainage
-During dehumidifying modes, remove the
upper drain plug from the back of the unit,
install the drain connector(5/8" universal
female mender) with 3/4" hose(locally
purchased). For the models without drain
connector, just attach the drain hose to the
hole. Place the open end of the hose directly
over the drain area in your basement floor,
or into a bucket.
Remove the
upper drain plug
√
Continuous
drain hose
-When the water level of the bottom tray reaches
a predetermined level, the unit beeps 8 times,
the digital display area shows "P1" . At this time
the air conditioning/dehumidification process will
immediately stop. However, the fan motor will
continue to operate(this is normal). Carefully move
the unit to a drain location, remove the bottom drain
plug and let the water drain away. Reinstall the bottom
drain plug and restart the machine until the "P1"
symbol disappears. If the error repeats, call for
service.
NOTE: Be sure to reinstall the bottom drain plug firmly
to prevent leakage before using the unit.
-Press this button, the selected temperature will increase(cooling) or decrease(heating) by
1°C/1°F 30 minutes.The temperature will then increase (cooling) or decrease (heating) by
another 1°C/1°F after an additional 30 minutes. This new temperature will be maintained
for 7 hours before it returns to the originally selected temperature. This ends the Sleep/Eco
mode and the unit will continue to operate as originally programmed.
NOTE: This feature is unavailable under FAN or DRY mode.
SLEEP/ECO operation
Содержание P-12NPE
Страница 1: ...For any service needs call 1 855 368 8606 OWNER SMANUAL MODEL P 08NPE P 12NPE P 14NPE...
Страница 16: ......