Congratulations on the purchase of your new Magnaflux  

MD-2030 Magnetic Particle Inspection Machine! This guide 

will help you install and set-up your new Magnaflux machine.  

If you have any questions, please contact your local 

Magnaflux Authorized Service Center or call Magnaflux 

Customer Service at 847-657-5300.  

Содержание MD-2030 Series

Страница 1: ...tulations on the purchase of your new Magnaflux MD 2030 Magnetic Particle Inspection Machine This guide will help you install and set up your new Magnaflux machine If you have any questions please contact your local Magnaflux Authorized Service Center or call Magnaflux Customer Service at 847 657 5300 ...

Страница 2: ...Connect the incoming power to the Incoming Power Connection located inside the unit on the back side Attach the Chassis Ground wire to the inside of the unit to the Chassis Ground Connection Screw Follow all local electrical codes for wiring It is high ly recommended that an electrical fused disconnect be installed on the headstock side of the unit Either on the wall behind the unit or on a pedest...

Страница 3: ...Factors for Resistance Welders NPFA National Electric Code 2011 Some areas refer to 2 phase instead of 1 phase The incoming power goes directly to an isolation transformer so the unit will operate identically on 1 or 2 phase power Electrical Input Input Volts AC Phase Full Load Amps Recommended Line Fuse Amps Recommended Wire Size AWG 208 3 265 225 2 230 3 240 200 4 380 3 150 125 4 415 3 135 125 6...

Страница 4: ...ontamination is not introduced into the machine s inspection bath Contamination may include but not limited to grinding dust tool ing oil or coolant metal shavings wheelabrator sandblasting residue and paint chips Ways to prevent contamination include locating the machine in a dedicated room providing positive air pressure inside the Equipment Enclosure Hood Assembly keeping the front cur tain of ...

Страница 5: ...d transformer will mount on the tailstock end of the unit and plug into the 115 outlet located there Enclosure Foot Print Open Dimensions Closed Dimensions Model Length Depth Height Length Depth Height Standard unit 86 218 cm 50 127 cm 120 305 cm 86 218 cm 73 185 cm 89 5 227 cm Long unit MD 2030L 135 336 cm 50 127 cm 120 305 cm 135 336 cm 73 185 cm 89 5 227 cm Extra long unit MD 2030XL 178 452 cm ...