Magna Systems ThermoBiscuit Скачать руководство пользователя страница 1

 

 

 

 

 

 

 

 

Quick Star

t

 Guide   

 

for

 

Ther

mo

Bis

cuit

 

 

 

 

 

 

 

 

Wirele

ss

 8

-

Ch

annel

 

Thermocoupl

e Monitor

 

for

 

Extreme 

Tem

perature Env

i

ronments

 

 

 

 

 

 

 

 

 

 

Copyright 

 2008 by Magna Systems, L.L.C. 

 

Revision 0.2 

 

 

 

 

 

 

 

  (03/2009)

Содержание ThermoBiscuit

Страница 1: ...Quick Start Guide for ThermoBiscuit Wireless 8 Channel Thermocouple Monitor for Extreme Temperature Environments Copyright 2008 by Magna Systems L L C Revision 0 2 03 2009...

Страница 2: ...Rev 0 2 2 This page intentionally left blank...

Страница 3: ...e DataLink display but it will not be saved to your data file 7 To set up in Data Logging Mode follow DataLink Data Logger Instructions included below 8 Verify proper thermocouple operation by watchin...

Страница 4: ...ntrol Panel System General for Window XP Service Pack 2 or later version Excel Application Help About Microsoft Excel for Microsoft Excel 2002 or later version Step 2 Install DataLink software Step 3...

Страница 5: ...Rev 0 2 5 Step 5 A window Found New Hardware Wizard appears Select No not this time Step 6 Select Install the software automatically...

Страница 6: ...Rev 0 2 6 Step 7 Window operating system shall locate USBXpress Device automatic ally Step 8 USB driver shall now be Installed successfully...

Страница 7: ...r ThermoSleeve Step 1 Before positioning ThermoBiscuit inside an environment chamber installThermoSleeve onto ThermoBiscuit Step 2 Remove ThermoSleeve away from ThermoBiscuit after the set of hardware...

Страница 8: ...he module to a measurement location such as an oven Remember to copy down the key code to access the module memory later Step 8 Exit DataLink Step 9 Once the test measurement is complete open DataLink...

Страница 9: ...the time when the data retrieving mode is activated instead of the actual data collection time In order to reduce this time stamp discrepancy activate Start Collection as soon as the node is reconnect...

Страница 10: ...the following procedure Step 8 Restart the DataLink and Select Repeat an Existing Test Step 9 Remove the batteries from the module S N 6051 and reinstall them on the module Step 10 Select the test con...

Страница 11: ...stance value shall be greater than 1000 Ohms Otherwise it indicates that the power circuitry is damaged due to wrong battery installation Step 18 Send the module S N 6051 back to Magna Systems for an...