Page 18 of 22
508197-01
Issue 2137
Cleaning should be as often as necessary to keep the coil
clean. To clean the coil, remove the lower access panel
and blow out debris by using compressed air or water. Be
sure power to unit is shut off before using water to clean
the coil.
Care should be used when cleaning the coils so that
the coil fins are not damaged.
Accessories
The unit must be installed with approved wall sleeve and louver accessories for safe operation. Improper installations
could result in property damage, personal injury, or death.
WARNING
Refer to Table 9 for dimension information.
B
29-1/8
Required Wall Opening
C
Maximum Wall
Thickness
Exterior Wall
16
A
16-5/8
29
Wall Sleeve
Figure 11.
Motors
The indoor and outdoor fan motors are permanently
lubricated and require no maintenance.
Condensate Drain Pan
Foreign material should not be allowed to clog the drain
hole. Inspect and clear drain opening prior to cooling
season