12
1-13
It allows you to deactivate the ultrasonic sensor port by using remote start function. After
cancel remote start the input is activated again.
1-14
This function is available with CAN Bus module. In case you are using read only mode >
Magicar will only read data from CAN (trunk, door, hood). In read/write mode > data will read and
write to CAN (trunk, door, hood, lock and unlock, indicators, lock and unlock except closing
windows.). In mode 3 it iwill read/write and close windows > in this mode Magicar can close
windows when arming. This function is depending on car type.
Programming menu No.2
When the doors are opened and ignition is on, keep the buttons
I
and
IV
pressed for 2 sec.
Options
No.
Function
Button I
Button II
Button III
Button IV
2-01
Trunk output time
0.5 sec
2 sec
3 sec
4 sec
2-02
Door lock impulse
0.8 sec
4 sec
2 x 0.8 sec
15 sec
2-03
Door unlock impulse
0.8 sec
4 sec
2 x 0.8 sec
-
2-04
Door lock/unlock
impulse during remote
start
Off
Lock impulse
after remote start
Unlock impulse
before remote start
&lock impulse after
remote start
-
2-05
Door lock impulse after
remotely started engine
will go Off
Off
On
-
-
2-06
Parking lights
Normal mode
Continuous mode
Pulse mode
-
2-07
Start output (TACH)
ST-1 ST-2
ST-3
-
2-08
AUX 1
0.5 sec
5 sec
40 sec
Latch
2-09
AUX 2
0.5 sec
5 sec
40 sec
Latch
2-10
AUX 2 BYPASS
function
On Off
-
-
2-11
Shock sensor on/off
during AUX output
On Off
-
-
2-12
Cold start
Off
0 ºC
-5 ºC
-10 ºC
2-13
Arm/disarm by OEM
remote control
Enabled Disabled
Function explanation:
2-01
Impulse time set-up for trunk output.
2-02
Impulse time set-up for door lock.
2-03
Impulse time set-up for door unlock.
2-04
You can set the central door lock outputs reactions when remote starting activated. Advisable
if you need the door open at remote starting.
2-05
Option to lock the vehicle after remote starting.
2-06
Using this function, you can set the lights control by the alarm mode.
- normal – mainly for direct control of hazard lights by (-) or (+).
- 1-2 mode – designed to control hazard lights by the button (see page 13).
2-07
Duration of engine starting sequence.
2-08
Duration of negative impulse for AUX output No.1 (grounded when activated)
2-09
Duration of negative impulse for AUX output No.2 (grounded when activated)
2-10
It is possible to set the AUX output No 2 as a bypass output. In this case the output will be
activated when remotely started, and can be used e.g. for the transponder bypass module. When
remote starting is finished, the output will be deactivated.
2-11
It allows you to deactivate a shock sensor by using additional outputs in case connected
device is causing sensor reaction.
2-12
It allows you to set the temperature at which, if the regular starting function on, remote
starting will be carried out. But in case the temperature is higher than the pre-set one, starting will
not be carried out!
2-13
When function is enabled then is possible to arm and disarm system by Magicar
and factory remote controls. Function is only available when system is connected with
CAN Bus module.