MAGICFX
®
PSYCO2JET
—
User and Installation Manual
9
1.6
RAW MODE
In RAW mode, the operator controls the output of the MAGICFX
®
PSYCO2JET directly.
With DMX the operator controls the following variables:
• The angle of the rotating nozzle and output pipe, see figure
• The speed of rotation
• The output (CO
2
valve open or closed)
RAW mode is selected from the operator menu. Check Section 1.5 for the menu
structure.
0°
+90°
-90
°
OUTPUT PIPE
ROTATING NOZZLE
Output angle when facing the front side of the unit
In RAW mode the MAGICFX
®
PSYCO2JET is controlled with 1 safety address and 3
operational addresses.
DMX Address
Address range
Safety address
1 – 512
Start address (Angle)
1 – 510
Start a 1 (Speed)
2 – 511
Start a 2 (Output)
3 – 512
DMX addresses in RAW mode
The Safety address cannot be the same as one of the operational addresses.