Replacing the preistaltic tube of the dosing acid pump
Resilience D Installation guide. © 2016, all rights reserved
P a g e
|
33
REPLACING THE PREISTALTIC TUBE OF THE DOSING ACID PUMP
It is recommended to replace the check valve and internal tube of the dosing acid pump before starting a new bathing
season and/or every six months during the season. Please contact your local dealer to obtain a new tube. The internal
tube requires replacing when ACID PIPE message is visible.
WARNING: In order to perform this operation, you MUST wear rubber or polyethylene protective gloves
and safety glasses. It is also advisable to protect your clothes or wear dispensable ones.
Remove the transparent protective cover
Carefully slip off the rubber tube from its slot. Gently pull the
tube out (clock wise) assisting with the other hand to turn the
pump's engine wheel and help free the tube until it is
completely out.
Note:
It is advisable to flush the pump with running tap water in order to dilute any remaining acid which may
have spilled from the tube.
Disconnect both ends of the internal tube by
unscrewing the nuts from the nipples.
Screw in both ends of the NEW internal tube making
sure the nuts are tightly secured.