pH control
Resilience D Installation guide. © 2016, all rights reserved
P a g e
|
30
CELL CLEANING MODE
The dosing acid pump system ensures the cell remains clean by automatically washing it with acid when the
circulation pump is off. The factory preset allows a cell wash after the circulation pump logs at least 6 hours of run
time (e.g. level 9).
A small amount of acid is used (approximately 70 cc / 2.5 oz), so the cleaning function has virtually no influence on
the pH level in an averaged size pool. In small bodies of water or in acidic environments, the automatic cleaning
should be scheduled less frequently.
Adjusting the frequency of the cleaning
1.
Turn the circulation pump OFF, then press the "MODE" button to get
to the "CELL CLEANING: AUTO" mode.
2.
Use the buttons to adjust the cleaning level (e.g. Level 3).
LVL 0 = No cleaning.
LVL 9 = most frequent cleaning.
Immediately initiating a cell cleaning
1.
Turn the circulation pump OFF, then press the "MODE" button to
get to the "CELL CLEANING: MANUAL" mode.
2.
Use the buttons to adjust the cleaning level (e.g. Level 3).
LVL 1 uses 1 unit of acid.
LVL 4 uses 4 units of acid.
NOTE: the cleaning process can take more than 1 hour. If the cell
remains calcified, purge it out by turning the circulation pump on for
a few minutes, and then repeat the cleaning function.
Turning the circulation pump ON cancels this manual cleaning function.
NOTE: In cases that the automatic settings of the dosing acid pump does not reduce the pool's pH level or
doesn't keep the cell clear, make sure that the acid container is full and that the suction tube is installed
properly.