background image

 U-Link TRx User Guide  

 

 

Ref. 

09-03-V1.0 

    p 

 
This input is protected against reverse polarity, and short transient voltage by a Transil protection. 
 
 
 
 
 
 
 
 
 
 
 
 
 
A light continuously on when the transceiver is powered on. The color of this light is changed according to the selected serial 

link mode (RS232 

Æ

 Green, or RS422 

Æ

 Red). Corresponding marking of the light shall indicate “ON 

 

Serial link wiring 

U- link Trx proposes 2 types of serial link : RS232 and RS422. No hardware flow control is used. 

RS232 wiring       RS422 

wiring 

 

 

 

 

 

RF Modes 

Two RF modes are identified : 

 

A UHF transmit only function. This transmitter is used with a Global Navigation Satellite System (GNSS) base station 
and broadcast GNSS differential message around the area of the base. The transmitter is available with different 
output power( 0.5W, 2W, and 4W). The UHF transmitter is controlled and monitored by the connected GNSS unit 
through remote control commands. 

 

A UHF relay with receive and transmit functions. This transceiver is able to receive GNSS differential message from a 
base, and re-broadcast these data at the same frequency in order to increase the range of the radio link between a 

GNSS base and a rover. This transceiver is intended to be used as an autonomous device and can be 

controlled and 

monitored by software, run on PC.

 

 

Switch 1 allows the selection of the mode according the following schemes : 
 

 
 
 
 
 
 
 
 

 

+ DC Supply -.

 

+

 

-

 

ON

 

ON

1     2 

TX-RX

 

power
Power

ground

ON

 

TX-RX

 

RS232

Rx Data

RS232

Tx Data

Signal

ground

ON

 

1     2 

Switch 2 low 

(“OFF”) to  select 

RS232 mode

power
Power

ground

ON

 

TX-RX

RS422 

TX+

Signal

ground

ON

 

1     2 

Switch 2 high 

(“ON”) to select  

RS422 mode 

RS422 

TX-

RS422 

RX+

RS422

RX-

 

ON

 

ON

 

1     2 

TX-RX

RELAY mode

Switch1 low (“OFF”)

ON

 

TX-RX

TRANSMIT 

mode 

Switch 1 high 

(“ON”)

 

ON

1     2 

Содержание U-Link TRx

Страница 1: ...PRELIMINARY U Link TRx Radio DATA MODEM User Guide ...

Страница 2: ...electronic or paper version photocopy without MAGELLAN consent This document is subject to change without notice All trademarks mentioned in this guide are the property of their respective owner MAGELLAN Zac de la FLEURIAYE BP60 433 44474 CARQUEFOU Ref 09 03 V1 0 ...

Страница 3: ...t Power supply 2 Serial link wiring 3 RS232 wiring RS422 wiring 3 RF Modes 3 Framing Modes 4 Transparent Mode 4 DSNP Mode 4 Operating modes 5 Command mode 5 Normal mode 5 AT commands 6 General commands 6 Registers description 6 Electrical Specifications 7 About this document This guide describes the U Link TRx devices their options and accessories ...

Страница 4: ...a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help CHANGES OR MODIFICATIONS NOT EXPRESSLY APPROVED BY MAGELLAN COULD VOID THE USER S AUTHORITY TO OPERATE THE EQUIPMENT RF Exposure Warning During operation the user may keep a minimum separation distance of 1 meter with the RF devices Overview The modem is the new MAGELL...

Страница 5: ...th different output power 0 5W 2W and 4W The UHF transmitter is controlled and monitored by the connected GNSS unit through remote control commands A UHF relay with receive and transmit functions This transceiver is able to receive GNSS differential message from a base and re broadcast these data at the same frequency in order to increase the range of the radio link between a GNSS base and a rover...

Страница 6: ...scribed below Transparent Mode In transparent mode data transmitted on serial link are rough data without frame coding DSNP Mode Data sent to the serial link must be the following Type Content Length Synchronization block Start of text ASCII Character STX 1 char Type of message C P R T X char 1 char Address Station number in BCD 1 char Length of message Length of the message 1 or 2 char s Cadence ...

Страница 7: ...onfiguration registers using AT command In command mode the UHF receiver or transmitter is inhibited Rx and Tx excepted when using test command Entering command mode issues on the serial link a sequence The sequence of three consecutive characters is accepted only if no character have been sent before and after the sequence Register S214 defines the silence duration Exiting command mode return int...

Страница 8: ... that S235 is not restored by ATR Test modes ATT1 Pure carrier transmission using current channel The output of this mode is achieved by reception of any character on the serial link ATT2 Modulation using current channel Modulation 55 hex data The output of this mode is achieved by reception of any character on the serial link ATT3 Modulation using current channel Modulation with 512 bits pseudo r...

Страница 9: ... Command time out Time out duration for detecting the pattern unit in ms From 3 up to 240ms 100 Miscellaneous R W S233 Transmited Call Sign S233 NZI206211 FCC ID product reference NZI206211 1 R W S234 Call sign activation 0 Æ disabled 1 Æ enabled When enabled transmit to the air the FCC ID by using international Morse code with a carrier at 1200Hz for short or long The Morse code data rate shall b...

Страница 10: ... 5 modulation with raw data throughput of 9600 bits s Transmitter output power The RF output power on 50ohms load is software selectable between 0 5W 27dBm 2W 33dBm and 4W 36dBm Receiver RF sensitivity The digital sensitivity is typically 110 dBm at 10 5 BER RF Connector The RF connector is a 50 ohms standard TNC female connector Antenna The product will be used with the PROCOM ANTENNA FSP70 460 F...

Отзывы: