background image

The 2WPGM is a two-way wireless PGM, which 
also provides one zone input. After assigning 
the PGM module to a system, the PGM can be 
programmed to activate and deactivate, as 
detailed in the system’s programming guide. 

Location and Mounting

The 2WPGM must be installed within 35 m 
(115 ft.) of the control panel. Before you mount 
the 2WPGM, perform the signal strength tests 
to ensure optimal performance of the unit. 

Do not cut, bend, or alter the antenna.

         Avoid mounting the PGM module near or
         on metal, as this may affect transmission.

Powering the Unit

The unit requires either AC or DC power input. 
For wire connections, see Figure 1.

AC: 6 Vac (500 mA) to 16.5 Vac (200 mA)
DC: 5 Vdc (500 mA) to 24 Vdc (200 mA)

The external power supply used with this 
module must be of an Approved/Certified type, 
acceptable to the authorities where the module 
is installed and used.

Enrollment and Testing

Jumper 2 (JP2) is used for enrolling (Learn 
mode) and for testing signal strength. 

Learn Mode: 

Remove and re-install JP2.

Signal Strength: 

Perform a transmission by 

temporarily removing and re-installing JP2, or by 
opening the zone that is connected to the PGM. 
To interpret the RSSI LED, see the LED 
Indicators table.

To test the signal strength of the 2WPGM at the 
control panel, see the control panel’s

 

programming guide. 

Normal Operation: 

JP2 must be 

CLOSED

 for 

normal operation.

Zone Setting

ZONE Jumper determines the input setting of 
the zone. 

ZONE 

CLOSED

 = Normally Closed (N.C.) zone

                            (default)

ZONE 

OPEN

     = Normally Open (N.O.)

                            zone

Do not use EOL resistors with universal/zone

          inputs.

Figure 1

Instructions

Two-way Wireless PGM

2WPGM (433/868MHz)

V1.1

Printed in Canada 10/2015    www.paradox.com    2WPGM-EI05

ZONE

JP2

AC/DC 
Power

PGM 
Output

Door 
Contact

Antenna

Relay

LED Indicator

LED Indicator