MAG TOOLS ET250 Скачать руководство пользователя страница 6

1 689 989 380 | 2018-08-01

Robert Bosch GmbH

1.6.7 Danger of tripping

 WARNING

When conducting tests or making adjustments,

the sensor and connection cables increase the

risk of tripping.

Route the connecting cables such that any risk

of tripping up is prevented.

---Separator---

1.6.8 Noise

 WARNING

Noise levels in excess of 70 dB(A) can occur

when measurements are carried out on a vehi-

cle, especially at high engine speeds. Damage

to hearing may result if human beings are ex-

posed to noise at such levels over an extended

period of time.

Noise protection facilities must be provided by

the owner at all workplaces in the vicinity of

the testing area.

Suitable personal noise protection facilities

must be used by the operator.

---Separator---

2. Guideline and standards

2.1 EMC

The ET250 satisfies the criteria of EMC directive

2014/30/EC.
The ET250 is a class/category-A product according to

EN 61 326-1. The ET250 may cause high-frequency

household interference (radio interference) so that in-

terference suppression may be necessary. In such ca-

ses, the operator may be required to take appropriate

action.

---Separator---

2.2 Open-source software (OSS)

For an overview of the open-source software licenses

for the ET250, see "Settings >> Legal notes".

---Separator---

3. Product description

3.1 Intended use

The ET250 is a battery-powered diagnostic device for

workshops that can be used for control unit diagnosis.

It is prohibited to pass it on to end consumers.

---Separator---

3.2 Foreseeable misuse

Misuse ( ) with corresponding intended use ( ):

The ET250 is passed on to end consumers.

The ET250 may only be operated by trained work-

shop personnel.

---Separator---

The ET250 is operated by the driver of a vehicle

while driving.

The ET250 may only be operated by trained and in-

structed passengers while driving.

---Separator---

3.3 Scope of delivery

Denomination

Order number

ET250

Case

Power supply unit

1 687 023 736

USB connecting cable

1 684 465 491

OBD connection cable

1 684 465 756

WLAN USB adapter

Original operating instructions and related

documents

---Separator---

The order numbers are not part numbers. The or-

der numbers are used to identify the items inclu-

ded in the scope of delivery. Components that

can be ordered are identified as spare parts or

wearing parts.

---Separator---

3.4 ET250 overview

1

2

 

1:

 

ET250

1 Power key

2 Touchscreen

---Separator---

3.5 Symbols on the rating plate

Attention: general warning sign indicating

danger. Before commissioning, connecting

and using Bosch products, it is essential to

read the operating instructions and the safe-

ty instructions, in particular, carefully.

---Separator---

Dispose of used electrical and electronic de-

vices, including cables, accessories and bat-

teries, separately from household waste.

---Separator---

EU declaration of conformity

---Separator---

en | 6 | ET250 | Guideline and standards

Содержание ET250

Страница 1: ...Diagnostic device ET250 en Original operating instructions Diagnostic device ...

Страница 2: ...6 3 3 Scope of delivery 6 3 4 ET250 overview 6 3 5 Symbols on the rating plate 6 3 6 Functional description 7 3 6 1 Interfaces 7 3 6 2 Network port 7 3 6 3 Storage battery 7 3 6 4 Operating system 7 3 6 5 Status LED 7 4 Initial Operation 7 4 1 Setting up the ET250 7 4 2 Setting up a printer 8 4 3 Licensing the software 8 5 Operation 8 5 1 Switching on the ET250 8 5 2 Activating power saving mode 8...

Страница 3: ...sts of your own safety and will ulti mately help avoid damage to the device When a Bosch product is handed over to another person not only the operating instructions but also the safety instructions and information on its designated use must be handed over to the person Separator 1 5 Warranty and Liability By using the product you agree to the following regula tions Copyright Software and data are...

Страница 4: ... that all test connections are properly plugged in and secure Before disconnecting the B cable from the engine ground or battery B switch off the ig nition Never open the enclosures Separator 1 6 1 2 High voltages in hybrid vehicles and electric vehicles as well as their high voltagecomponents WARNING If high voltage components or high voltage wires are inexpertly handled there is a risk of fatal ...

Страница 5: ...wn first thendisconnect the plug of the fan motor Separator 1 6 4 Danger of burning WARNING When working on a hot engine there is a risk of injury from burning if such components as the exhaust gas manifold the turbocharger the Lambda sensor etc are touched or if parts of the body come too close to them These com ponents may be heated to temperatures of sev eral hundred degrees Celsius Depending o...

Страница 6: ...50 is a battery powered diagnostic device for workshops that can be used for control unit diagnosis It is prohibited to pass it on to end consumers Separator 3 2 Foreseeable misuse Misuse with corresponding intended use The ET250 is passed on to end consumers The ET250 may only be operated by trained work shop personnel Separator The ET250 is operated by the driver of a vehicle while driving The E...

Страница 7: ...attery The storage battery is permanently integrated into the housing and cannot be changed from the outside The fully charged storage battery of the ET250 is de signed to guarantee approx 2 hours of independent op eration The ET250 can be operated with the following voltage supply Storage battery Power supply unit OBD connection cable With the OBD connection cable plugged in the ET250 is supplied...

Страница 8: ...ower saving mode Press power key briefly The ET250 will enter standby mode power saving mode If power saving mode is already active it will be deactivated For further information see the ET250 Help Cen ter ET250 main menu Help Center Separator 5 3 Switching off the ET250 1 Press the power key for approx 2 seconds and re lease it when the selection menu is opened 2 Select Switch off The ET250 will ...

Страница 9: ...f the ET250 is to be sold reset the ET250 to factory settings This deletes all data and settings from the ET250 e g license information log files user settings test protocols images Restore the system by following the instructions from the ET250 Help Center For further information see the ET250 Help Cen ter ET250 main menu Help Center Separator 5 8 Opening the Help Center For further information s...

Страница 10: ...ion 7 2 V 2600 mAh typ Dimensions W x H x D 295 x 180 x 40 mm Weight with battery without power sup ply unit 1 2 kg Degree of protection IP 20 Maximum operating altitude with power supply unit 2000 m Maximum operating altitude without power supply unit 4000 m Voltage supply from the vehicle via OBD 10 V 28 V Voltage supply from the vehicle via OBD 1 6 A Operating Temperature 0 C 40 C 32 F 104 F St...

Страница 11: ...1 689 989 380 2018 08 01 Robert Bosch GmbH ET250 11 en ...

Страница 12: ...1 689 989 380 2018 08 01 Robert Bosch GmbH LastPage ET250 11 en Robert Bosch GmbH Franz Oechsle Str 4 73207 Plochingen Deutschland www bosch com bosch prueftechnik bosch com 1 689 989 380 2018 08 01 ...