MAINTENANCE WORK
COMPRESSED AIR SYSTEM
68
Maintenance manual MT 25 / 30 YT
Dewater compressed air tank
The dried compressed air always has a remaining humidity.
The moisture condensates in the compressed air system and
collects in the compressed air tanks.
Every compressed air tank features a dewatering valve, by
which you can drain the condensation water.
Fig. 41: Dewatering valve
X
Park the MT on level ground.
X
Stop the motor and withdraw the ignition key.
X
Open the valve by pulling the ring in the direction of the
arrow.
3
The water can drain.
X
Keep the ring pulled until no more water comes out.
C h e ck i n c a s e o f h e av y wa t e r c o l l e c t i o n , w h e t h e r t h e
f u n c t i o n o f t h e a i r d r ye r c a r t r i d g e i s s t i l l g i ve n a n d
r e p l a c e i f n e c e s s a r y,
s e e “ R e p l a c e a i r d r ye r c a r t r i d g e ”
.