6.2
Syntax #1: TCP/UDP/SMS
General Reports
:
@ <ID>, <MSG#>, <PF>, <GPS>, <BV>, <RSSI>, <STARTER>, <IGNIT>, <D>, <T>,
<LT>, <LN>, <AL>, <SP>, <DIR>, <SAT>, <HDOP>, <MI> !
Event
number
(MSG#)
Description
Details
531
Location report on demand (command SG531)
Alert send directly after reception, send
position if good fix, if no GPS send last know
position
551
External starter relay status change (command
SG551)
same as 531
701
Periodic reporting heartbeat while powered
On each timer, send position if good fix, if no
GPS send last know position
702
Periodic reporting with wired ignition ON
When DI1 is High, same as 701
703
Periodic reporting while virtual ignition ON
When supply voltage is > BVC, same as 701
704
Periodic reporting while GPS ignition ON
When GPS position is moving, same as 701
705
Periodic reporting with wired ignition OFF
When DI1 is Low, same as 701
706
Periodic reporting while virtual ignition OFF
When supply voltage is < BVC - 0.8V, same
as 701
707
Periodic reporting while battery is disconnected
When main input voltage < 9V, same as 701
708
Periodic reporting when speed threshold exceeded
When speed is > TH_SP, same as 701
601
Alert message when power up/reset
When unit power cycle happen and GPS has
good fix, send report
605
Alert message when direction change threshold
exceeded
When direction between two position change
> TH_DC, same as 531
606
Alert message when speed threshold exceeded
When speed > TH_SP, same as 531
607
Alert message when mileage threshold exceeded /
reach 65000 miles
When mileage > TH_MI or 65000 miles,
same as 531
608
Alert message when battery Voltage below
threshold
When main input voltage < TH_BAT, same
as 531
609
Alert message when battery disconnected
When main input voltage < 9V, same as 531
610
Alert message when battery re-connected
When main input back on 12V or more,
same as 531
611
Alert message when wired ignition ON detected
When DI1 is High, same as 531
612
Alert message when virtual ignition ON detected
When supply voltage is > BVC, same as 531
613
Alert message when GPS ignition ON detected
When GPS position is moving, same as 531
614
Alert message when wired ignition OFF detected
When DI1 is Low, same as 531
615
Alert message when virtual ignition OFF detected
When supply voltage is < BVC - 0.8V, same
as 531
616
Alert message when idle period threshold
exceeded
When ignition is on, and position not moving
for time > IDT, same as 531
617
Alert message when towing detected
When GPS speed > 5mph, same as 531
618
Alert message when towing stopped
After 617, when speed < 5mph, same as 531
619
Alert message when analog input over limit is
breached
When AI1 > AI_H, same as 531
620
Alert message when analog input go back to
normal range
After 619 or 621 and AI_L < AI1 < AI_H,
same as 531
621
Alert message when analog input under limit is
breached
When AI1 < AI_L, same as 531
48
Confidential, the whole document is the sole property of Maestro Wireless Solutions ltd.
3603-9, 36/F., 118 Connaught Road West, Sheung Wan, Hong Kong