Manual
maMoS
100/200/300/400
Picture 15.
The PWM output and the load connection.
One of the two connectors:
12V
or
VCC
(+5V) (Picture 15.) can be used for sup-
plying the receiver controlled via the output. If the 12V supply is used the maximum load
current amounts 500mA, whereas for the 5V supply it is 200mA.
3.3.4. Relay outputs (optional)
Optionally the monitor can be equipped with two independent
SPDT
relays
Re-
lay #1
and
Relay #2
connected with a connector as shown in Picture 16. The B ending is a
common ending, the A ending is a normally closed ending (
NC
) and the C ending is a nor-
mally open ending (
NO
). The
Relay #1
is connected with the
A1
,
B1
and
C1
connectors,
whereas the
Relay #2
is connected with
A2
,
B2
and
C2
. The relays enable the user to
switch voltages up to 230V and currents below 2A.
The relays can:
−
be controlled by one of the analogue outputs
U1
÷
U4
,
I1
÷
I4
(according to
the level of signal on the analogue output the relay either switches on or off
with a certain hysteresis).
−
be controlled by the digital input (the relay follows the
In1
or
In2
digital input
state, which means it switches on when the input is active and switches off
when it is inactive).
−
work according to the measurement cycle stage (the relay switches on in the
“
MEASUREMENT"
stage and switches off during other stages)
−
be permanently switched off.