Manual
maMoS
100/200/300/400
3.3. Electric connectors of the monitor
Picture 12.
Location of the inputs, outputs and power supply connectors
The
maMoS
monitor has a number of electric connectors which enable the user to
connect the monitor to a power supply and additional devices. All the inputs, outputs and
power supply connectors are to be found inside the monitor on the device main board (Pic-
ture 12.). The wires should be connected as described in section 4.1.1. Each of the in-
puts and outputs can perform several functions which can be defined with the help of the
MaMoSII.exe
software. The PC and the dryer connector are to be found at the bottom of
the monitor casing (Picture 7.).
3.3.1. Digital inputs
The monitor has two digital inputs which can be configured by the user:
In1
and
In2
. According to the settings the inputs can be used for:
−
restarting the measurement cycle (which means aborting the current cycle
regardless of its stage and starting the new cycle with the ventilation
process),
−
controlling (switching on or off) any of two relays