Leak Detection & Automatic Shut-Off System 

for Conventional Vent Gas Water Heaters 

with Gas Flow Interrupter

Congratulations on your purchase of a FloodMaster RS-094-MK5 water heater leak detection 

system from Reliance Detection Technologies. This product is designed to automatically shut 

off the water supply to a water heater or tank if a leak is detected. This kit also provides output 

signal capabilities to shut down gas flow when a leak is detected.
To ensure proper installation and to maximize the performance of your RS-094-MK5 water leak 

detection system, please read this manual thoroughly before installing or operating the system.   

PLEASE READ CAREFULLY BEFORE PROCEEDING:

If a leak is detected, the RS-094-MK5 will shut off the water going to the water heater. This will 

stop the continuous flow of water from the water supply to the tank. However, all or some of 

the water that is already in the tank may still leak out onto the floor.

NOTE: This installation and operating manual contains important information about the operation of the 

RS-094-MK5 system. If this system is being installed for use by a different user, please be sure a copy of 

this manual is left with the system for future reference.

www.RelianceDetection.com        Toll-Free: 888-771-4929

RS-094-MK5 System Components (included in kit):

1 – Receiver box / actuator 
1 –  3/4” full port lead-free shut-off valve 

(NSF/ANSI 61 and 372) 

1 – Power supply with 12’ lead wire 

1 – Water sensor with 8’ lead wire
1 – Metal plate for sensor placement 
1 – Gas flow interrupter

RS-094-MK5

Содержание RS-094-MK5

Страница 1: ...LLY BEFORE PROCEEDING If a leak is detected the RS 094 MK5 will shut off the water going to the water heater This will stop the continuous flow of water from the water supply to the tank However all or some of the water that is already in the tank may still leak out onto the floor NOTE This installation and operating manual contains important information about the operation of the RS 094 MK5 syste...

Страница 2: ...tally or vertically in conjunction with the metal plate see Figure 3 Clean the desired location area to ensure the surface is clean for optimum plate adhesion Peel the backing off the metal plate to reveal the adhesive and stick in place Place the sensor on the plate as close as possible to the floor allowing the magnets to secure it in place Note The sensor features a through hole that can be use...

Страница 3: ...4 3 5 3 0 3 1 1 5 3 0 1 4 2 5 4 1 4 1 1 1 350 4 9 1 FRONT VIEW BACK VIEW 2 6 2 56 Ø 12 THRU 1 77 02 1 48 1 69 8 FT LEAD 30 04 PIN OFFSET FROM SURFACE Ø 25 30 Ø 38 x 82 7 8 9 See RS 094 technical data submittal sheet for valve dimensions FIGURE 2 WIRING DIAGRAM FIGURE 3 SENSOR INSTALLATION OPTIONS 11 POWER SUPPLY RS 094 1 2 3 4 5 6 7 8 9 GREEN GREEN FIGURE 1 KIT PREWIRED AT FACTORY 1 89 12 FT LEAD ...

Страница 4: ...pen the valve and begin the flow of water again The green Power indicator light on the receiver will flash once to confirm the reset Light the water heater pilot and confirm gas flow to the water heater MAINTENANCE Test the system annually per the function test install step 10 to ensure correct operation and maintain product warranty status At a minimum exercise press and release the Reset button ...

Отзывы: