Installation and Maintenance
M4168 and M4169 Drum Level Sensors
English
Madison Company, Inc.
27 Business Park Drive
Branford, CT 06405
MADE IN THE USA
Made in the USA
203-488-4477 or 800-466-5383
www.madisonco.com
Sensing Solutions since 1959
General Information:
M4168-x and M4169-x
•
Available for high level signal, low level signal, or high
and low level signals.
•
Designed with liquid tight fittings, allowing for usage
both indoors and outdoors.
•
Optional alarm enclosures are available, see part
number chart below.
•
If a non-contact sensor is required for the application,
please refer to Madison ultrasonic and radar level
sensors at www.madisonco.com.
Installation Instructions:
M4168-x and M4169-x
•
Apply a suitable thread sealant to the threads.
•
Tighten into 3/4” bung of drum, 1/2 turn beyond hand
tight.
Electrical Specifications:
Alarm Enclosures:
021-P00008
•
Fixed mount design. Will be threaded onto the stem
assembly during assembly.
•
Can be wired for High Level, Low Level or both, see
part number chart below.
•
Standard design with LED’s for alarm. Audible piezos
may be used in place of or in conjunction with LED’s.
•
Top level part, M4168-x or M4169-x, must be ordered
with this alarm, this can not be installed by the end
user
021-P00009
•
Remote mount design. Uses liquid tight fitting to
secure cable to enclosure.
•
Can be wired for High Level, Low Level or both, see
part number chart below.
•
Standard design with LED’s for alarm. Audible piezos
may be used in place of or in conjunction with LED’s.
•
Top level part, M4168-x or M4169-x, can be ordered
with the alarm or the alarm can be ordered separately.
This alarm enclosure can be installed by the end user.
© 2018 Madison Company, Inc., MAD_MAN_MF-027_060518
ECN #10900, Effective Date 08/2018, MF-027, Rev D
General Information:
M4168-x and M4169-x
Installation Instructions:
M4168-x and M4169-x
• Apply a suitable thread sealant to the threads.
• Tighten into
3
/
4
" bung of drum,
1
/
2
turn beyond hand tight.
Alarm Enclosures:
021-P00008
• Fixed mount design. Will be threaded onto the stem
assembly during assembly.
• Can be wired for High Level, Low Level or both, see part
number chart below.
• Standard design with LED’s for alarm. Audible piezos
may be used in place of or in conjunction with LED’s.
• Top level part, M4168-x or M4169-x, must be ordered
with this alarm, this can not be installed by the end user.
021-P00009
• Remote mount design. Uses liquid tight fitting to secure
cable to enclosure.
• Can be wired for High Level, Low Level or both, see part
number chart below.
• Standard design with LED’s for alarm. Audible piezos
may be used in place of or in conjunction with LED’s.
• Top level part, M4168-x or M4169-x, can be ordered with
the alarm or the alarm can be ordered separately. This
alarm enclosure can be installed by the end user.
Electrical Specifications:
Part Number
M4168-1
M4168-1-FM
M4168-1-RM
M4168-2
M4168-2-FM
M4168-2-RM
M4168-3
M4168-3-FM
M4168-3-RM
M4169-1
M4169-1-FM
M4169-1-RM
M4169-2
M4169-2-FM
M4169-2-RM
M4169-3
M4169-3-FM
M4169-3-RM
Operation
(dry condition)
NO
NO
NO
NC
NC
NC
NO / NC
NO / NC
NO / NC
NO
NO
NO
NC
NC
NC
NO / NC
NO / NC
NO / NC
Function
High Level
High Level
High Level
Low level
Low level
Low level
High level / Low level
High level / Low level
High level / Low level
High level
High level
High level
Low level
Low level
Low level
High level / Low level
High level / Low level
High level / Low level
Stem Length
(inches)
2.00
2.00
2.00
32.00
32.00
32.00
32.00
32.00
32.00
2.00
2.00
2.00
32.00
32.00
32.00
32.00
32.00
32.00
Alarm
Enclosure
No
Yes
Yes
No
Yes
Yes
No
Yes
Yes
No
Yes
Yes
No
Yes
Yes
No
Yes
Yes
20, 30, 55
Gallon Drum
20, 30, 55
20, 30, 55
20, 30, 55
55
55
55
55
55
55
20, 30, 55
20, 30, 55
20, 30, 55
55
55
55
55
55
55
Watts
30
30
30
30
Voltage
240 VAC
120 VAC
120 VDC
24 VDC
Amps
(resistive)
0.14 A
0.28 A
0.07 A
0.28 A
Approvals:
Installation and Maintenance
M4168 and M4169 Drum Level Sensors
Madison Company
27 Business Park Drive Branford, CT 06405
(203) 488-4477 • Fax (203) 481-5036
E-mail: [email protected]
www.madisonco.com
English • Español
ECN #
107
02
• Effective Date
01/30/2018
• MF-027, Rev.
C
ISO 9001 Certified
• Available for high level signal, low level signal, or high and low level signals.
• Designed with liquid tight fittings, allowing for usage both indoors and outdoors.
• Optional alarm enclosures are available, see part number chart below.
• If a non-contact sensor is required for the application, please refer to Madison
ultrasonic and radar level sensors at www.madisonco.com.
General Information:
M4168-x and M4169-x
Installation Instructions:
M4168-x and M4169-x
• Apply a suitable thread sealant to the threads.
• Tighten into
3
/
4
" bung of drum,
1
/
2
turn beyond hand tight.
Alarm Enclosures:
021-P00008
• Fixed mount design. Will be threaded onto the stem
assembly during assembly.
• Can be wired for High Level, Low Level or both, see part
number chart below.
• Standard design with LED’s for alarm. Audible piezos
may be used in place of or in conjunction with LED’s.
• Top level part, M4168-x or M4169-x, must be ordered
with this alarm, this can not be installed by the end user.
021-P00009
• Remote mount design. Uses liquid tight fitting to secure
cable to enclosure.
• Can be wired for High Level, Low Level or both, see part
number chart below.
• Standard design with LED’s for alarm. Audible piezos
may be used in place of or in conjunction with LED’s.
• Top level part, M4168-x or M4169-x, can be ordered with
the alarm or the alarm can be ordered separately. This
alarm enclosure can be installed by the end user.
Electrical Specifications:
Part Number
M4168-1
M4168-1-FM
M4168-1-RM
M4168-2
M4168-2-FM
M4168-2-RM
M4168-3
M4168-3-FM
M4168-3-RM
M4169-1
M4169-1-FM
M4169-1-RM
M4169-2
M4169-2-FM
M4169-2-RM
M4169-3
M4169-3-FM
M4169-3-RM
Operation
(dry condition)
NO
NO
NO
NC
NC
NC
NO / NC
NO / NC
NO / NC
NO
NO
NO
NC
NC
NC
NO / NC
NO / NC
NO / NC
Function
High Level
High Level
High Level
Low level
Low level
Low level
High level / Low level
High level / Low level
High level / Low level
High level
High level
High level
Low level
Low level
Low level
High level / Low level
High level / Low level
High level / Low level
Stem Length
(inches)
2.00
2.00
2.00
32.00
32.00
32.00
32.00
32.00
32.00
2.00
2.00
2.00
32.00
32.00
32.00
32.00
32.00
32.00
Alarm
Enclosure
No
Yes
Yes
No
Yes
Yes
No
Yes
Yes
No
Yes
Yes
No
Yes
Yes
No
Yes
Yes
20, 30, 55
Gallon Drum
20, 30, 55
20, 30, 55
20, 30, 55
55
55
55
55
55
55
20, 30, 55
20, 30, 55
20, 30, 55
55
55
55
55
55
55
Watts
30
30
30
30
Voltage
240 VAC
120 VAC
120 VDC
24 VDC
Amps
(resistive)
0.14 A
0.28 A
0.07 A
0.28 A
Approvals:
Installation and Maintenance
M4168 and M4169 Drum Level Sensors
Madison Company
27 Business Park Drive Branford, CT 06405
(203) 488-4477 • Fax (203) 481-5036
E-mail: [email protected]
www.madisonco.com
English • Español
ECN #
107
02
• Effective Date
01/30/2018
• MF-027, Rev.
C
ISO 9001 Certified
• Available for high level signal, low level signal, or high and low level signals.
• Designed with liquid tight fittings, allowing for usage both indoors and outdoors.
• Optional alarm enclosures are available, see part number chart below.
• If a non-contact sensor is required for the application, please refer to Madison
ultrasonic and radar level sensors at www.madisonco.com.
ISO 9001 Certified