Summer Eco 

INVERTER POOL HEAT PUMP 

 

 

 
 
 

 

 

USER'S MANUAL

 

 

Содержание Summer Eco SUME100/240MM

Страница 1: ...Summer Eco INVERTER POOL HEAT PUMP USER S MANUAL ...

Страница 2: ......

Страница 3: ...11 1 Installation requirments 11 2 Placing the unit and water connections 12 3 Wiring 13 4 Electric wiring Diagram 13 5 Reference for protecting devices and cable specification 13 E Operation guidance 14 1 Controller overview and key Function 14 2 Controller functions and settings 15 F Testing 16 1 Heat pump checks before use 16 2 Refrigerant leak detection method 16 3 Trial run 16 4 Running statu...

Страница 4: ...the Madimack high efficiency inverter pool heat pump All our heat pumps are built and designed to the highest standard and are protected by our extended warranty service for peace of mind We hope you enjoy using our heat pumps Thank you ...

Страница 5: ...tion to a procedure practice or the like which if not correctly performed or adhered to could result in personal injury or injury to a third party These signs are rare but are extremely important a Keep the heat pump away from fire sources b It must be placed in a well ventilated area indoor or enclosed areas are not allowed c Repair and disposal must be carried out by trained service personnel a ...

Страница 6: ...ced and may damage the machine h Do not use or stock combustible gas or liquids such as thinners paint and fuel to avoid fire i In order to optimize the heating effect please install heat preservation insulation on pipes between swimming pool and the heater and please use a recommended cover on the swimming pool j Connecting pipes of the swimming pool and the heater should be less than 10m 3 Safet...

Страница 7: ...nside the heat pump may be damaged 2 Accessories 3 Features a Stable DC inverter compressor b EEV Technology c Quick hot gas defrosting with Saginomiya 4 way valve d High efficiency twisted titanium heat exchanger e High pressure and low pressure protection f Soft start wide voltage application g Stable inverter control system ...

Страница 8: ...temperature range of ambient Air 15 25 5 Introduction of different modes a The heat pump has two modes Boost and Silence b They have different strengths under different conditions Mode Modes Strength Boost mode Heating capacity 20 to 100 capacity Intelligent optimization Fast heating Silent mode Heating capacity 20 to 80 capacity Sound level 3dB A lower than Boost mode ...

Страница 9: ...wer kW 0 21 1 07 0 29 1 50 0 32 1 67 0 45 2 38 0 50 2 60 0 62 3 21 0 76 4 25 Rated input current A 0 94 4 88 1 32 6 82 1 47 7 58 2 05 10 80 2 27 11 84 2 80 14 61 3 44 19 32 Maximum input current A 6 5 8 9 5 12 5 17 19 5 20 Sound level at 10m dB A 19 8 31 2 21 8 32 1 21 6 33 5 23 9 34 26 2 37 3 26 3 38 1 26 9 38 7 Advised water flux m h 2 4 2 4 3 5 4 6 6 8 7 10 10 12 Water connection mm 40 Remarks ...

Страница 10: ...ubject to adjustment periodically for improvement without further notice A B C D E F G H SUME60 240MM 324 560 348 349 872 250 74 654 SUME80 240MM 324 560 348 349 872 250 74 654 SUME100 240MM 324 560 348 349 872 250 74 654 SUME130 240MM 324 560 348 349 872 290 74 654 SUME160 240MM 324 590 348 349 962 350 74 654 SUME200 240MM 324 590 348 349 962 390 74 754 SUME250 240MM 404 720 388 429 1084 620 74 9...

Страница 11: ...ndards of their current state or local governing body for all electrical mechanical and water services to prevent danger or damage to the unit a Location and clearances The inverter pool heat pump should be installed in a well ventilated place b Typical plumbing installation diagram Please note water connection locations may differ from the diagram and are for illustration only ...

Страница 12: ...f air reduces the efficiency of the heater and could damage the unit If the machine needs an appended pump not supplied The recommended pump must adhere to the specification flux please refer to the Technical Parameters b Water connections and condensation The inlet and outlet water unions should not be installed with soft flexible pipes The heat pump must be connected with rigid pipes When the ma...

Страница 13: ... 5 Reference for protecting devices and cable specification Above data is subject to modification without notice Note The above data is associated to power cables less than 10m If power cable is longer than 10m the wire diameter must be increased in accordance with current regulations The signal cable can be extended to a maximum of 50m MODEL SUME60 240MM SUME80 240MM SUME110 240MM SUME13 0 240MM ...

Страница 14: ...mbol Designation Function ON OFF Power On Off Boost Mode Press to start Boost mode Silence Mode Press to start Silence mode UP DOWN Temperature Setting Displaying Attention The controller has a built in memory so all parameters are saved in the event of power loss ...

Страница 15: ... mode is set to full power boost mode b Defrosting Automatic active defrosting When machine is defrosting starts flashing after defrosting is on continuously Forced defrosting When the machine is heating and the compressor is working continuously for 10 minutes In heating mode press and on controller simultaneously for 5 seconds to start forced defrosting when symbol is flashing defrost starts whe...

Страница 16: ... your local service center 3 Trialrun a The circulation pump must start before the heat pump and stop after the heat pump to avoid any damage occurring to the machine b Before starting the heat pump please check for any leaks of water or other dangers c In order to protect the heat pump pool heater the machine is equipped with a time lag start function the fan will run 1 minute earlier than the co...

Страница 17: ...nough water flow is detected The Heat Pump has a large range operation up to a seven degree differential If the temperature differential is above 8 degrees the flow switch or E6 Error will be displayed indicating not enough flow detected Recommended procedure a Fully open all valves including the by pass and switch the unit on to max temp b If Error E3 is displayed slowly close by pass valve until...

Страница 18: ...k bolts cables and connections regularly 4 If repairs or removal is required please contact an authorized service center 5 Do not attempt to work on the equipment by yourself Improper operation may cause danger 6 To reduce risks safety inspections must be carried before the maintenance or repairing for heat pumps with R32 gas Important Unscrew the water nozzle of inlet pipe to let the water flow o...

Страница 19: ...ation d Vacuum system completely before welding Welding should only be carried out by professional person in a service center 2 Failure solution and code Failure Reason Solution Heat pump doesn t run No power Wait until the power recovers Power switch is off Switch on the power Fuse may be broken Check and change the fuse The circuit breaker is off Check and turn on the breaker Fan running but wit...

Страница 20: ...de 7 P0 Controller communication failure 8 P1 Water inlet temp sensor failure 9 P2 Water outlet temp sensor failure 10 P3 Gas exhaust temp sensor failure 11 P4 Evaporator coil pipe temp sensor failure 12 P5 Gas return temp sensor failure 13 P6 Cooling coil pipe temp sensor failure 14 P7 Ambient temp sensor failure 15 P8 Cooling plate sensor failure 16 P9 Current sensor failure 17 PA Restart memory...

Страница 21: ...I Appendix Power Cable Breaker fuse Not Supplied Earth Power Supply 230V 50Hz Water pump 230V less than 500W Water Pump Water Pump Breaker fuse Not Supplied Power Supply 230V 50Hz Earth ...

Страница 22: ...Breaker fuse Not supplied Earth Power Supply 230V 50Hz Water pump 230V over 500W Water Pump Water Pump Breaker fuse Not supplied Power Supply 230V 50Hz Earth Power Cable Contactor ...

Страница 23: ...ion 1 Water pump timer 2 Water pump wiring of Heat Pump Note The installer should connect 1 parallel with 2 as above picture To start the water pump condition 1 or 2 is connected To stop the water pump both 1 and 2 should be disconnected ...

Страница 24: ... Components c Installation Green Network connection Orange No network Red Failure Screw base on back panel Slide WIFi box into base Connect cable b Installation position Base Terminal WiFi Box WiFi Button Indicator light ...

Страница 25: ...will flash Android mobile please download from iPhone please download from b Enter Configure new device in APP follow indication to finish binding Select WiFi Select WiFi No device if already configured please make sure on the same WiFi network Configure new device Confirm Please enter password ...

Страница 26: ... speak to your electrician to expand WiFi network 2 The weather forecast is for reference only This App is subject to updating without notice On Off Weather Temperature setting Timer Mode Setting Menu Silence Boost Mode Heat Cool Silence Boost Mode Temperature setting On Off Weather Timer Mode Setting Menu ...

Страница 27: ...www Madimack com au ...