background image

Code 5000078C - 08/2020 - R1

INSTRUCTIONS FOR INSTALLATION, USE 

AND MAINTENANCE

Arrow

EVO

 Standalone

Translation of the original instructions.

Before installing and using the device, carefully read this manual and store 

it together with the product.

wM-Bus radio module

EN

Code

Содержание Arrow EVO Standalone

Страница 1: ...ONS FOR INSTALLATION USE AND MAINTENANCE ArrowEVO Standalone Translation of the original instructions Before installing and using the device carefully read this manual and store it together with the p...

Страница 2: ...website www maddalena it Warranty limitations Maddalena S p A declines all responsibili ty with immediate invalidation of the war ranty in relation to Damage or defects caused by transport or loading...

Страница 3: ...ts where it will be exposed to atmospheric agents The device must always be pro tected from extreme humidity and heat Penetration of humidity and intense heat may damage the bat tery and the device If...

Страница 4: ...nical fraud cable cutting ArrowEVO Standalone is compliant with the wM Bus data communication protocol de fined at European level by Standard EN 13757 This guarantees a high level of inter operability...

Страница 5: ...for this association performed during installa tion the serial number of the mechanical meter and the serial number of module ArrowEVO Standalone 1 1839012370 A ARROW EVO P N 1 ETRMD 0001 S N 1234567...

Страница 6: ...U 2017 2102 OMS Radio Standard Wireless M Bus OMS Modes C1 Default T1 Optional Operating frequency range 868 0 868 6 868 7 869 2 MHz Radiated power max 14dBm Range 500 m in line of sight Reference sta...

Страница 7: ...C 10x 10x l WARNING The instruction manual is an inte gral part of the device and should be carefully read and stored d PROHIBITED Packaging material must be prop erly disposed of and kept out of chil...

Страница 8: ...external pulse genera tor by appropriately connecting the wires The ArrowEVO Standalone module is sup plied with a four pole cable with earth 1 White pulse input Pulse signal for both the delivery an...

Страница 9: ...pos sible Fix the ring nut 1 to a pipe 2 using a clamp or to a wall 3 using the plugs provided Insert the module fully into the guide Preferably install the module with the antenna symbol 4 facing up...

Страница 10: ...f zero If the meter on which the radio module is installed has a reading other than zero synchronisation of the mechanical meter reading and radio module is recommended using the programming kit Simpl...

Страница 11: ...ctivated using the magnetic programming key use the part of the screen shown in the box 1 Once the desired parameters have been set activate programming for initial installation using the button 2 2 1...

Страница 12: ...tion and num ber of transmissions performed Battery life depends largely on the frequen cy of data transmission set 4 2 Cleaning No particular cleaning procedures are required However the installation...

Страница 13: ...13...

Страница 14: ...14...

Страница 15: ...15...

Страница 16: ...right to change its products at any time and without prior notice with the aim of improving them and without compromising primary features All the graphic illustrations and or photographs appearing i...

Отзывы: