Page
31
of
63
Traverse Motor
–
Powered Traverse Hoist Only
In this section it will explain the correct procedure on removing and reinstalling the Traverse
Motor for servicing procedures or replacement.
Removal
Step 1
–
Remove external covers of the Hoist (refer to section 9.1)
Step 2
–
Remove the PCB from the hoist (refer to section 9.2)
Step 3
–
Using a 5mm Allen key remove the two M6 x 40 bolts. (arrowed)
Step 4
–
Slide the motor off the traverse shaft by pulling the Motor away from the Chassis
Refitting / Replacement
Step 5 - Refitting is a reversal of the removal process noting the following point:
A)
Ensure the Traverse Motor is attached in the correct orientation, allowing the motor
to align with the motor mounts.