Flowrate units
Select the units and the timebase from the drop down list boxes. This sets the units on the logged value.
Polynomial coefficients
The polynomial coefficients listed i are related to the following equation:
Cross-Sectional Area = A + B*X +C*X
2
+ D*X
3
+ E*X
4
+ F*X
5
Where X = depth of stream The coefficients are listed in order A, B, C, D, E, F.
Siltation depth
This parameter can be used to correct the calculated flow rate if a known amount of silt is inside the pipe. The
depth of silt will be subtracted from the area calculation in order to calculate the corrected flow rate.
Depth limit
When the cross-sectional area of a stream is calculated using the polynomial coefficient method, the user
must set the “
Depth limit
” at which the polynomial reaches a maximum. For example, if a channel has a
maximum depth of 1.0m the “
Depth limit
” should be set at 1.0m as well. Alternatively the “
Depth limit
” can
be set within
FloCalc
and the procedure described for importing polynomial coefficients.
Import parameters from FloCalc
If the user does not know the coefficients for the polynomial equation, they can be calculated using the
MACE utility "
FloCalc
"
Using MACE "FloCalc" to calculate polynomial coefficients
The Mace utility program "
FloCalc
" (download separately from www.macemeters.com) can be used to draw
regular and irregular channel shapes. These shapes are then converted into a 5th order polynomial. Their
coefficients can be imported directly into the appropriate fields in
MACE XCi User Manual - 180 -
Содержание HydroMace XCi
Страница 1: ......
Страница 13: ...MACE XCi User Manual 13...
Страница 19: ...MACE XCi User Manual 19...
Страница 33: ...MACE XCi User Manual 33...
Страница 36: ...MACE XCi User Manual 36...
Страница 167: ...NOTE None of these parameters can be edited MACE XCi User Manual 167...
Страница 182: ...MACE XCi User Manual 182...
Страница 187: ...MACE XCi User Manual 187...
Страница 200: ...NOTE In the example the Net flowrate will be the sum of Flow Rate 1 Flow Rate 2 Flow Rate 3 MACE XCi User Manual 200...
Страница 260: ...5 Tighten all three screws 6 Reconnect the battery cable assembly to the backplane board MACE XCi User Manual 260...
Страница 265: ...MACE XCi User Manual 265...