214658
91
Revision A
Calibrating Auto Header Height Control (Case Combines with Version 28.00 or Higher Software)
NOTE:
Changes may have been made to combine controls or display since this document was published. Refer to
combine operator
’
s manual for updates.
1009753
A
Figure 6.40: Case IH Combine Display
1.
Select TOOLBOX on the MAIN page, and then select
HEADER SETUP.
2.
Locate HEADER SUB TYPE field. It will be located on
either the HEAD 1 or HEAD 2 tab.
3.
Select 2000 (A).
1009754
A
B
Figure 6.41: Case IH Combine Display
4.
Locate the HEADER SENSORS and HEADER
PRESSURE FLOAT fields. They will be located on
either the HEAD 1 or the HEAD 2 tab.
5.
Select ENABLE (A) in the HEADER SENSORS field.
6.
Select NO (B) in HEADER PRESSURE FLOAT field.
1009755
A
B
Figure 6.42: Case IH Combine Display
7.
Engage separator and header, and press preset 1 or 2.
8.
Ensure AUTO HEIGHT icon (A) appears on display and
is shown at location (B) as shown. When the header is
set for cutting on the ground, this verifies that the
combine is using the potentiometers on the header
correctly to sense ground pressure.
NOTE:
AUTO HEIGHT field (B) may appear on any of the RUN
tabs and not necessarily on RUN 1 tab.