215104
145
Revision A
4.8.3
Displaying Header Sensor Input Signals
You can display individual sensor input signals in the event of a malfunction or as part of a troubleshooting routine.
NOTE:
The header
MUST
be attached to the windrower to perform this procedure. The cab display module (CDM) automatically
adjusts its programming for each header.
1011772
C###
E###
WINDROWER SETUP?
NO/YES
A
B
Figure 4.108: CDM Programming Buttons
1.
Turn the ignition key to RUN, or start the engine.
2.
Press PROGRAM (A) and SELECT (B) on the CDM to enter
programming mode.
•
WINDROWER SETUP? is displayed on the upper line.
•
NO/YES is displayed on the lower line.
1011785
CXXX
EXXX
DIAGNOSTIC MODE?
NO/YES
A
B
Figure 4.109: Diagnostic Functions
3.
Press SELECT (B) until DIAGNOSTIC MODE? is displayed on
the upper line.
•
NO/YES is displayed on the lower line.
4.
Press right arrow (A) to select YES. Press SELECT (B).
•
VIEW ERROR CODES? is displayed on the upper line.
5.
Press SELECT (B) until READ SENSOR SETUP? is displayed on
the upper line.
•
NO/YES is displayed on the lower line.
1011812
CXXX
EXXX
SENSOR INPUT
HDR HEIGHT 1.23 V
C
C
B
A
D
Figure 4.110: Header Sensors
6.
Press right arrow (C) to select YES. Press SELECT (D).
•
SENSOR INPUT is displayed on the upper line.
•
HDR HEIGHT 1.23 V is displayed on the lower line.
7.
Press left (B) or right (C) arrow to cycle between individual
sensor readers.
8.
Press SELECT (D) to skip to EXIT READ SENSORS? selection.
9.
Press right arrow (C) to select YES. Press SELECT.
10. Press PROGRAM (A) to exit programming mode or press
SELECT (D) to proceed to next diagnostic mode.