215104
138
Revision A
4.6.3
Calibrating the Header Float Sensors
NOTE:
•
The header
MUST
be attached to the windrower to perform this procedure. The cab display module (CDM)
automatically adjusts its programming for each header.
•
Use the left or right FLOAT buttons on the CDM to perform this procedure.
1021948
A
Figure 4.91: Float Pin
–
Right Side
IMPORTANT:
Ensure float pins (A) are installed in the working position.
1011772
C###
E###
WINDROWER SETUP?
NO/YES
A
B
Figure 4.92: CDM Programming Buttons
1.
Start the engine.
2.
Press PROGRAM (A) and SELECT (B) on the CDM to enter
programming mode.
•
WINDROWER SETUP? is displayed on the upper line.
3.
Press SELECT (B) until CALIBRATE SENSORS? is displayed on
the upper line.
•
NO/YES is displayed on the lower line.
1011781
CXXX
EXXX
CALIBRATING FLOAT
PRESS FLOAT + TO START
C
B
A
Figure 4.93: Header Float Display
4.
Press right arrow (B) to select YES. Press SELECT (C).
•
TO CALIBRATE SELECT is displayed in upper line.
5.
Press left arrow (A) or right arrow (B) until HEADER FLOAT
is displayed on the lower line. Press SELECT (C).
•
CALIBRATING FLOAT is displayed on the upper line.
•
PRESS FLOAT + TO START is displayed on the lower line.