215104
123
Revision A
4.4
Activating Cab Display Lockouts
You can lock some header functions to prevent changes to settings. Use this feature to keep header settings constant when
there are multiple Operators.
NOTE:
FUNCTION LOCKED flashes on CDM when locked header function switch is pressed.
4.4.1
Activating the Header Tilt Control Lockout
NOTE:
•
The header
MUST
be attached to the windrower to perform this procedure. The cab display module (CDM)
automatically adjusts its programming for each header.
1011786
CXXX
EXXX
WINDROWER SETUP?
NO/YES
A
B
C
Figure 4.55: CDM Programming Buttons
1.
Turn the ignition key to RUN, or start the engine.
2.
Press PROGRAM (A) and SELECT (C) on the CDM to enter
programming mode.
•
WINDROWER SETUP? is displayed on the upper line.
•
NO/YES is displayed on the lower line.
3.
Press right arrow (B) to select YES. Press SELECT (C).
•
SET KNIFE SPEED? is displayed on the upper line.
1011824
CXXX
EXXX
NO/YES
SET CONTROL LOCKS?
B
A
Figure 4.56: Control Locks
4.
Press SELECT (B) until SET CONTROL LOCKS? is displayed on
the upper line.
•
NO/YES is displayed on the lower line.
5.