215104
88
Revision A
Table 3.4 Engine Start Troubleshooting
Problem
Solution
Controls not in NEUTRAL
•
Move GSL to NEUTRAL
•
Move steering wheel to locked (centered) position
•
Disengage HEADER switch
Operator
’
s station not locked
•
Adjust position of operator
’
s station
•
Ensure lock is engaged
Neutral interlock misadjusted
•
Refer to the windrower technical manual
No fuel to engine
•
Fill empty fuel tank
•
Replace clogged filter
•
Ensure fuel shut off valve is in open position
Old fuel in tank
•
Drain tank
•
Refill with fresh fuel
Water, dirt, or air in fuel system
•
Drain, flush, fill, and prime system
Improper type of fuel
•
Drain tank
•
Refill with correct fuel
Crankcase oil too heavy
•
Replace with recommended oil
Low battery output
•
Test the battery
•
Check battery electrolyte level
Poor battery connection
•
Clean and tighten loose connections
Faulty starter
•
Refer to the windrower technical manual
Wiring shorted, circuit breaker open
•
Check continuity of wiring and breaker (manually reset)
Faulty injectors
•
Refer to the windrower technical manual