214325
193
Revision A
Figure 5.115: Scroll Wheel for Adjustments
The scroll wheel (A) is on right of Tyton terminal.
Figure 5.116: Header Control Cluster
Header height setpoint control dial (A) is on header control
cluster.
5.1.8
John Deere 50 Series Combines
Output Voltage Range
The auto header height sensor output must be within a specific range, or feature will not work properly.
Combine
Low Voltage Limit
High Voltage Limit
Minimum Range
John Deere 50 Series
0.7 V
4.3 V
3.0 V
Check sensor
’
s output voltage range from combine cab or manually at float indicator box according to instructions
that follow.
Manually Checking Output Voltage Range
To manually check sensor
’
s output voltage range, follow these steps: