Figure 5.62: Challenger Combine Display
2.
Press HEADER CONTROL button (A). The HEADER
CONTROL page appears. You can adjust sensitivity on
this page using up and down arrows.
Figure 5.63: Challenger Combine Display
3.
Adjust sensitivity to maximum setting.
4.
Activate AHHC, and press HEADER LOWER button on
control handle.
5.
Decrease sensitivity until feeder house remains steady
and does not bounce up and down.
NOTE:
This is maximum sensitivity and is only an initial setting.
The final setting must be made in field as system
reaction will vary with changing surfaces and operating
conditions.
NOTE:
If maximum sensitivity is not needed, a less sensitive
setting will reduce frequency of header height
corrections and component wear. Partially opening
accumulator valve will cushion action of header lift
cylinders and reduce header hunting.
5.1.5
Gleaner R62/R72 Combines
System Requirements (Gleaner R62/R72)
NOTE:
Changes may have been made to combine controls or display since this document was published. Refer to
combine operator
’
s manual for updates.
The following system components are required in order for auto header height control (AHHC) system to work:
•
Main module (PCB board) and header driver module (PCB board) mounted in card box in fuse panel
module (FP)
•
Multi-Function Control Handle operator inputs
•
Operator inputs mounted in control console module (CC) panel
NOTE:
In addition to components listed above, electro hydraulic header lift control valve is an integral part of system.
Содержание FFT FD75
Страница 2: ...FD75 FlexDraper Combine Header Published June 2017...
Страница 10: ......
Страница 24: ......
Страница 148: ......
Страница 188: ...214325 178 Revision A Figure 5 82 Combine Heads Up Display SETTING UP AUTO HEADER HEIGHT CONTROL...
Страница 282: ......
Страница 288: ......
Страница 304: ......
Страница 307: ......