214323
184
Revision B
1010070
Figure 4.112: Float Indicator
1.
Lower the header to the desired cutting height or ground
pressure setting. The float indicator (the white module on
top of the adapter) should be set to 1.5.
1003735
A
Figure 4.113: CLAAS Combine Display, Console, and
Joystick
2.
Push and hold the left side of header raise/lower switch (A)
until an alert sounds.
NOTE:
Two different cutting heights can be programmed.
4.10.3
Setting Sensitivity of Auto Header Height Control
–
CLAAS 600 and 700 Series
Setting the sensitivity of the auto header height control (AHHC) system on a CLAAS 600 or 700 Series combine affects how
quickly the AHHC system changes the height of the header.
NOTE:
Changes may have been made to the combine controls or the display since this document was published. Refer to the
combine operator
’
s manual for updated information.