![MacDon D1 Series Скачать руководство пользователя страница 212](http://html.mh-extra.com/html/macdon/d1-series/d1-series_unloading-and-assembly-instructions_685658212.webp)
215184
188
Revision A
6.2.5
Converting from Medium Configuration to Wide Configuration or Ultra Wide
Configuration
1032272
3
A
A
1
2
A
A
Figure 6.29: Auger Configurations
–
Rear View
1 - Medium
Configuration
2 - Wide
Configuration
3 - Ultra Wide
Configuration
When converting from Medium configuration to Wide
configuration, you will need to remove existing flightings (A)
from the auger and add auger fingers. When converting from
Medium configuration to Ultra Wide configuration, you will
need to remove all existing bolt-on flightings (A) from the auger
and add augur fingers.
Four flighting plugs (MD #213084), M6 hex head bolts
(MD #252703), and M6 tee nuts (MD #197263) are needed to
cover exposed flighting mounting holes after the flightings are
removed. These parts can be ordered from a MacDon Dealer.
1.
Improve access and ease installation by removing the float module from the combine. For instructions, refer to the
header operator
’
s manual or technical manual.
NOTE:
Some parts have been removed from the illustrations for clarity.
To convert from Medium configuration to Wide configuration, follow these steps:
1026204
B
D
A
C
Figure 6.30: Right Side of Medium Configuration
2.
Remove bolts (A) and access cover (B). Retain for
reassembly.
3.
Remove hardware from locations (C), and remove bolt-on
flighting (D) from the feed auger.