OM-154 500 Page 8
Table 3-1. Suggested Welding Settings
Wire Type,
Shielding Gas,
And Flow Rate
Wire
Diameter
(inch)
Operator
Control
Settings
Material Thickness
Wire Speed*
E70S-6
CO
20 cfh+
2
E70S-6
75% Argon
25% CO 2
20 cfh+
E71T-GS
Flux Core
ER 308
Stainless
Steel
Tri-Mix
20 cfh+
Aluminum
Argon
30 cfh+
.023
.030
.035
.023
.030
.035
.030
.035
.023
.030
.035
.030
.035
1/4 in.
(6.4 mm)
3/16 in.
(4.8 mm)
1/8 in.
(3.2 mm) 14 ga. 16 ga. 18 ga. 22 ga.
24 ga.
–
–
4
80
4
65
–
–
4
90
4
75
3
40
3
60
4
100
4
75
4
60
4
90
4
85
4
100
4
75
4
60
4
100
3
80
3
70
3
65
3
50
4
100
4
75
4
60
3
85
4
85
3
80
3
60
3
50
3
90
3
70
3
60
2
45
2
40
3
90
3
65
3
50
3
80
3
85
2
2
1
1
1
70
60
55
45
35
2
2
1
1
–
60
50
40
30
–
2
1
1
1
–
40
30
20
15
–
2
2
1
1
1
80
70
60
50
40
2
2
1
1
–
60
50
30
45
2
2
1
3
–
50
40
33
25
–
1
1
1
–
–
40
30
20
–
–
1
1
1
–
–
30
20
10
–
–
3
3
2
1
–
85
75
70
60
–
2
2
3
–
–
60
55
50
–
–
–
–
–
–
–
–
–
–
–
2
1
1
–
–
90
90
85
–
–
2
2
1
–
–
90
90
80
–
–
–
–
Voltage
Voltage
Voltage
Voltage
Voltage
Voltage
Voltage
Voltage
Voltage
Voltage
Voltage
Voltage
Voltage
Wire Speed*
Wire Speed*
Wire Speed*
Wire Speed*
Wire Speed*
Wire Speed*
Wire Speed*
Wire Speed*
Wire Speed*
Wire Speed*
Wire Speed*
Wire Speed*
* Do not change Voltage Adjustment switch position while welding. Wire Speed Adjustment value in table is a starting value only, and Wire
Speed Adjustment control setting can be fine tuned during welding.
+cfh = cubic ft per hour