OM-230 852 Page 15
5-6.
Selecting A Location And Connecting Input Power
Y
Special installation may be
required where gasoline or
volatile liquids are present −
see NEC Article 511 or CEC
Section 20.
Y
Installation must meet all Na-
tional and Local Codes −
have only qualified persons
make this installation.
Y
Disconnect and lockout/tag-
out input power before con-
necting input conductors
from unit.
Y
Always connect green or
green/yellow conductor to
supply grounding terminal
first, and never to a line ter-
minal.
1
Rating Label
Supply correct input power.
2
Black And White Input
Conductor (L1 And L2)
3
Green Or Green/Yellow
Grounding Conductor
4
Input Power Cord.
5
Disconnect Device (switch
shown in the OFF position)
6
Disconnect Device Grounding
Terminal
7
Disconnect Device Line
Terminals
Connect green or green/yellow
grounding conductor to disconnect
device grounding terminal first.
Connect input conductors L1 and
L2 to disconnect device line
terminals.
8
Receptacle (NEMA 6-50R)
Connect receptacle as shown.
9
Over-Current Protection
Select type and size of over-current
protection using Section 5-7 (fused
disconnect switch shown).
Close and secure door on disconnect
device. Remove lockout/tagout
device, and place switch in the On
position.
10 Plug (NEMA 6-50P)
Connect plug to receptacle.
ssb2.2* 1/94 − 804 622-A
18 in (457 mm) of
space for airflow
L1
L2
230 VAC, 1
8
Y
Do not move or operate
unit where it could tip.
10
1
1
=GND/PE Earth Ground
2
L1
L2
5
4
3
6
7
9
Содержание MW 185 Plus
Страница 2: ......
Страница 31: ...OM 230 852 Page 27 Notes...
Страница 32: ...OM 230 852 Page 28 SECTION 8 ELECTRICAL DIAGRAM Figure 8 1 Circuit Diagram...
Страница 33: ...OM 230 852 Page 29 228 180 A...
Страница 43: ...OM 230 852 Page 39 Notes...
Страница 49: ...Notes...
Страница 50: ...Notes Work like a Pro Pros weld and cut safely Read the safety rules at the beginning of this manual...